- ページ 4
インターホン・システム Altronics S 9413AのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Altronics S 9413A 8 ページ。 Video door intercom
VIDEO DOOR INTERCOM SYSTEM
Troubleshooting
Problem
No power (Power LED off)
Power LED dim
No picture
Specifications
Max cabling distance: ..........................................................................................50m (22AWG, 0.65mm 4 core)
Base Station
Voltage requirements: ................................................................................................................100-240V ~ 50Hz
Power consumption: ....................................................................................................Max 35VA, standby 1VA
Monitor screen: ..........................................................................................................................................B&W 4"
Call tone: ............................................................................................................................2 tone xylophone tune
Operating temperature: ..........................................................................................................................0 to 40°C
Weight: ..............................................................................................................................................................1.7kg
Dimensions: .................................................................................................................. 180W x 210H x 58D mm
Outdoor camera
Voltage requirements: ................................................................................................................................12V d.c.
Sensor: ....................................................................................................................................................CCD B&W
Viewing angle: ....................................................................................................................................................68°
Operating temperature:........................................................................................................................-40 to 75°C
Dimensions: ......................................................................................................................55W x 104H x 38D mm
Weight:............................................................................................................................................................380gm
Page 6
Cause
Insert power cord into power outlet. Ensure the ON/OFF
switch on the bottom of the unit is switched to ON.
Cabling between monitor and camera has a short circuit.
Check the brightness control. Ensure all wires are
connected to the correct terminals, ie: 1 to 1, 2 to 2 etc.