discharge at high current which caused
the temperature to rise above +40°C.
The temperature of the battery is very
different from ambient temperature
(typically a cold battery such as 0°C
connected to a CCPS in a heated room
such as 20°C).
The status LED is orange.
The status LED is OFF when the CCPS is
connected to the battery.
The Status LED is blinking red. The
battery is in defect mode.
Others
THE BATTERY DOES NOT GO TO TRICKLE CHARGE
(STATUS LED GREEN)
Possible causes
The battery is brand-new.
The duration of the balancing charge is
set to 48 hours during the assembly
process and increases automatically
during a period without charge.
The balancing charge duration has
increased because the battery was
partially charged for a few hours each
day.
The balancing charge duration has
increased because the battery was stored
for several weeks.
automatically when the temperature of
the battery will be between -10°C and
+40°C.
The charge phase will start
automatically when the temperature of
the battery will be close to the
temperature of the room (typically
when the temperature difference will
be lower than 10°C).
Check the connectors.
Check the CCPS.
If the connectors and the charger are
OK, return the battery to the after
sales service.
Press the gas gauge button, if the
battery stays in defect mode; return
the battery to the after sales service.
Return the battery to the after sales
service.
Actions
After several cycles of charge &
discharge with extended charges, the
duration of the balancing will be set to
its minimum value (4~5hours).
The battery can be used even if the
balancing phase is not finished but the
capacity of the battery will be slightly
reduced (> 95% capacity).
After several cycles of charge &
discharge with extended charges, the
duration of the balancing will be set to
its minimum value (4~5hours).
To avoid this phenomenon, avoid
charging the battery partially or charge
the battery for at least 12 hours.
After several cycles of charge &
discharge with extended charges, the
duration of the balancing will be set to
its minimum value (4~5hours).
To avoid this phenomenon, leave the
13