- ページ 3

計測機器 Akron 3462のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Akron 3462 17 ページ。 Forestry bumper monitor
Akron 3462 にも: 設置、操作、メンテナンスに関する説明書 (18 ページ)

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
Disconnect power and disable flow before maintenance.
Keep all personnel out of the Danger Zone (in front of the outlet of the monitor) when the
water source is attached. Dangerous flow velocities can cause serious injury.
The Bumper Monitor contains moving parts. Keep hands, fingers and objects away from
pinch points.
Not designed for explosive environments.
Exceeding the maximum pressure and flow of the Bumper Monitor or nozzle may cause
damage.
Do not disconnect Bumper Monitor from quick disconnect base while flowing.
Do not use the nozzle as a forcible entry tool.
Drain the monitor and nozzle after each use to prevent "freeze damage".
Do not install shutoffs on the outlet of the Bumper Monitor.
Use of hearing protection is recommended while operating.
Not recommended for use in saltwater applications.
For use with water or standard firefighting foams only. After use with foam, flush with fresh
water.
The Bumper Monitor, nozzle, logic box, control boxes and field adjustable rotation stops are
made for optimal performance. Do not alter in any manner.
Your Bumper Monitor and nozzle should be inspected prior and after each use, to ensure it is
in good operating condition. Periodically, an unanticipated incident may occur where the
Bumper Monitor is used in a manner that is inconsistent with standard operating practices and
those listed in IFSTA. A partial list of potential misuses follows:
There are many "tell-tale" signs that indicate repair is in order such as:
If any of the above situations are encountered, the Bumper Monitor should be taken out of
service and repaired, plus tested by qualified technicians, prior to placing it back in service.

General Instructions

Review the instructions, wiring diagram, component layout and rotational stops diagram before installing this unit. This unit
operates on 12 or 24 volt DC depending on the unit chosen. All electrical current flows through the wires. The Bumper
Monitor does not act as a ground.
PHONE: 800.228.1161 | WEBSITE: www.akronbrass.com
Sheet: 122386
STYLE 3462 FORESTRY BUMPER MONITOR
Operating above the maximum rated pressure and flow.
Not draining and allowing water to freeze inside the nozzle.
Dropping the nozzle from a height where damage is incurred.
Prolonged exposure to temperatures above +130° F, or below -25° F.
Operating in a corrosive environment.
Other misuse that might be unique to your specific firefighting environment.
Controls that are either inoperable or difficult to operate.
Excessive wear.
Poor discharge performance.
Water leaks.
Revision 12/2022
Page: 3 of 17