- ページ 11

食器洗い機 Asko D5223XXLCSのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Asko D5223XXLCS 16 ページ。 Xxl dishwasher
Asko D5223XXLCS にも: プランニング・デザイン・マニュアル (3 ページ)

Asko D5223XXLCS 取付説明書

CONNECTING THE WATER SUPPLY

In order to prevent heat damage to the inlet valve, all
solder connections must be made before the water supply
line is connected.
Flush the water supply line prior to connecting it to the
water fill tube.
The unit has a float switch in the base pan to protect
against flooding. If the inlet valve connection is not seated
properly, water may leak into the base pan and activate
the float switch.
It is important that the water supply line and the shut-off
valve have a sufficient flow volume. At last 3 gallons (12
liters) per minute must be able to pass through the line.
The water pressure should be 4.2-140 psi.
(1)
Water supply
(2)
Water supply valve (not supplied)
NOTE:
Be sure to run the PEX tubing through the hole to sink
compartment before moving the dishwasher into posi-
tion.

TESTING FOR LEAKS

1. Turn on the water supply and check for leaks.
2. Turn the power on at breaker/fuse box and test the
dishwasher operation by running a Rinse cycle. (This
should take about four minutes.)
3. Turn off the electrical power and check for leaks under
the dishwasher and sink.
4. Make sure that no kinks have developed in the drain
lines.
If there are no leaks and the dishwasher seems to be
working properly, continue with the installation.
Customer Care Center
1-800-898-1879
www.askousa.com
Page 11