- ページ 17
セキュリティシステム ACR Electronics RLB-41のPDF 製品サポートマニュアルをオンラインで閲覧またはダウンロードできます。ACR Electronics RLB-41 20 ページ。
7. Changing ownership or contact information
As the owner of the beacon, it is your responsibility to advise the national authority of any change in the information
provided on your registration form. If you are transferring the beacon to a new owner, you are required to provide the
national authority with the name and address of the new owner. You can do this by using their online database or by
letter, fax or telephone.
The new owner of the beacon is required to provide the national authority with all of the information requested on the
registration form. This obligation transfers to all subsequent owners. Registration forms for the United States are available
from NOAA by calling (888) 212-7283 (212-SAVE) or by registering online at www.beaconregistration.noaa.gov. Outside
the United States, the new owner may contact his local authority for the necessary form(s).
8. Lost or stolen beacons
If your beacon is lost or stolen, do the following immediately:
Report to your local law enforcement authorities that the EPIRB has been lost or stolen.
Contact NOAA at (888) 212-7283 (212-SAVE), or your national authority, with the following information:
Police department's name
o
Police department's phone number
o
Police case number
o
If someone attempts to register an EPIRB that has been reported as stolen, NOAA or your national authority will notify
the appropriate police department. Visit
APPENDIX A – TECHNICAL SPECIFICATIONS
GENERAL/ ENVIRONMENTAL
Beacon size (without
antenna)
Beacon weight
Beacon material
Color
Waterproof
Buoyant
Deployment
BATTERY
Operational life
Battery type and
replacement interval
Operating &
Storage temperatures
406 MHz TRANSMITTER
Frequency
Power output
Digital message format
Modulation type
121.5 MHz TRANSMITTER
Frequency
Power output
Modulation type
LED STROBE
http://www.cospas-sarsat.int/
8.13 in H x 4.28 in W
(206 mm H x 109 mm W)
27 oz (764 g)
High impact UV resistant polymer
ACR-Treuse™ (high visibility yellow)
Tested to 33 ft (10 m) for 5 min
Yes
Category I: Automatic hydrostatic release
Category II: Manual release
48 hours minimum @-4ºF (-20ºC) (Class 2)
USER REPLACEABLE. LiMnO
10 years from date of manufacture, or after use in an emergency.
Not to exceed battery expiration date.
-4º F to +131º F (-20º C to +55º C) (Class 2)
-22º F to +158º F (-30º C to +70º C) (Class 2)
406.040 MHz
5 W +/- 2dB
Standard location protocol (for the USA); The beacon can be reprogrammed at an
Authorized Battery Replacement center to other countries' coded formats.
Phase (16K0G1D)
121.5 MHz
50 mW +/- 3 dB
AM (3K20A3X)
for more detailed information.
2
17 |
P a g e