ASKOMA AHFR-H-B Series 피팅 지침, 사용자 설명서 및 서비스 - 페이지 3
{카테고리_이름} ASKOMA AHFR-H-B Series에 대한 피팅 지침, 사용자 설명서 및 서비스을 온라인으로 검색하거나 PDF를 다운로드하세요. ASKOMA AHFR-H-B Series 8 페이지. Flange heater
ASKOHEAT‐
F
Flange heater Ø 180 mm
Fitting instructions
Opera ng data, applica on, dimensions and model of the flange heater are on the iden fica on plate
and circuit diagram on the device, or can be found in the fi ng instruc ons / user manuals.
F o r s a f e t y r e a s o n s , t h e d e v i c e m a y n o t b e i n s t a l l e d f r o m a b o v e o r
b e l o w .
T h e d e v i c e m u s t b e i n s t a l l e d h o r i z o n t a l l y a n d e n s u r e t h a t t h e
" T O P " l a b e l p o i n t i s u p w a r d s .
Make sure that the hea ng tubes are en rely covered with liquid before placing into opera on.
The circula on of the liquid shall not be inhibited.
I m p o r t a n t i n f o r m a t i o n
If a heat exchanger is fi ed in the same tank, the controller must limit the temperature caused by the
heat exchanger to 85 °C. This prevents the safety temperature limiter of the flange heater tripping.
S a f e t y t e m p e r a t u r e l i m i t e r
The safety temperature limiter may trip at temperatures lower than approx. –15 °C (e. g. transporta-
on or storage). If this happens, press the reset bu on. See the sec on intended for experts in the user
manual.
T h e d e v i c e m a y o n l y b e u s e d t o h e a t w a t e r.
C o r r o s i o n p r o t e c t i o n
Please note:
This hea ng element is applicable in stainless steel boiler as well as in black steel / black steel enam-
elled boilers. Select the se ngs via DIP switch according to the boiler type.
For an installa on of the hea ng element into black steel or black steel enamelled boilers, the red slide
switch (DIP switch) has to be le in posi on "2" (factory se ng).
When installing the hea ng element into a stainless steel or chrome steel boiler, the slide switch
(DIP switch) has to be switched to posi on "ON".
In case of disregard corrosion damages on device and boiler could be caused.
ASKOHEAT‐
_180_2-9_en
MVGASV_120101_en_V3
www.askoma.com
Page 3
F