ASKOMA ASKOHEAT-F+ AHFR-BI-plus-5.8 피팅 지침, 사용자 설명서 및 서비스 - 페이지 6
{카테고리_이름} ASKOMA ASKOHEAT-F+ AHFR-BI-plus-5.8에 대한 피팅 지침, 사용자 설명서 및 서비스을 온라인으로 검색하거나 PDF를 다운로드하세요. ASKOMA ASKOHEAT-F+ AHFR-BI-plus-5.8 10 페이지.

ASKOHEAT
-F+
User manual
D e v i c e d e s c r i p t i o n
The ASKOHEAT
is switched in 7 steps via the digital Modbus interface or the analogue 0-10V input.
-F+
In addition, the maximum level up to 24 hours can be activated via the „Emergency On" button (Pos. 2)
or the digital input „Heat pump request".
The use of the interface is described in a separate document (Modbus protocl) and can be downloaded
from our homepage.
Te m p e r a t u r e c o n t r o l
The maximum temperature can be continuously adjusted with the rotary knob (pos. 1). The range ex-
tends from „Out" to approx. 85°C. For economic reasons, it should be set to approx. 65°C.
When the temperature is reached, the device switches off and on again automatically if necessary.
S a f e t y t e m p e r a t u r l i m i t e r
If the safety temperature limiter has tripped, you can reset it with a "00 screwdriver" through the
opening marked "Reset". This cannot be done until the temperature has cooled down by approx. 10K.
E m e r g e n c y o p e r a t i o n „ E m e r g e n c y O n "
The maximum heating output can be switched on immediately with the „Emergency On" button. To do
this, press the button for at least 2 seconds. This may be necessary in the event of a fault or if additio-
nal heat is required. To switch off, press the button again for at least 2 seconds. For safety reasons, the
ASKOHEAT
automatically switches back to normal operation after 24 hours.
-F+
A p p l i c a b l e
s t a n d a r d s
MV-012-6791.2
Flange heater Ø 180mm
for the user and qualified installer
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Safety:
EN60335-1 / -2-21 / -2-73
EMC:
EN55014-1 / -2
CEM:
EN62233
IP Code:
EN60529
01.11.2021
Temperature control
Emergency On
Reset button
Operating lights
www.askoma.com
Page 6