ASL INTERCOM BS 216 사용자 설명서
4.0

MAINS POWER

The BS 216 may be connected to the mains power outlet
to which other audio equipment is connected. The outlet
should have a clean earth. Avoid using mains power
outlets which also power dimmer controlled lighting
equipment.
The used AC power source can be anything from 100 -
240 V AC, 50/60 Hz. There is no need to adjust the unit to
the used mains voltage.
The power cord supplied with this unit carries the following
information label:
This appliance must be earthed
4.1
SAFETY EARTHING
The green-and-yellow wire of the mains cord must always
be connected to the electrical installation safety earth or
ground. It is essential for personal safety as well for proper
operation of the BS 216 and the other connected stations.
This wire is internally connected to all exposed metal
surfaces and any rack framework into which this unit might
be mounted is assumed to be connected to the same
grounding circuit.
4.2
POWERING UP
Powering up procedure:
-
Make sure that the red power switch on the left side of
the front panel is OFF.
-
Connect the power cord to the rear of the station.
-
Plug the other end of the power cord into a
PROPERLY GROUNDED outlet.
-
Turn on the power with the red button, the green power
LED will go on, indicating the station is active.
2
WARNING
IMPORTANT
The wires in this mains lead are colour coded in
accordance with the following code:
green and yellow
blue
Neutral
brown
Live
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
-
The wire which is coloured green-and-yellow must be
connected to the terminal in the plug which is marked
with the letter "E", or by the earth symbol which is
coloured green.
-
The wire which is coloured blue must be connected to
the terminal which is marked with the letter "N" or
coloured black.
-
The wire which is coloured brown must be connected
to the terminal which is marked with the letter "L" or
coloured red.
Those units that are supplied to the North American
market will have an integral moulded 3 pin connector
which is provided to satisfy required local standards.
User Manual BS 216 / Issue 1 © 1998 ASL Intercom, Utrecht, Holland.
Earth / safety ground
or