This section is intended for the engineer or technician responsible for installing
the DC60 resolver based encoder. Information in this chapter includes installation
guidelines, links to online CAD files, and mechanical drawings.

1.1 Installation Guidelines

1.1.1 Electrostatic Discharge Prevention

Electrostatic discharge can damage the DC60 if the discharge is through the I/O connector. Follow these
guidelines when handling the unit.
1) Touch a grounded object to discharge static potential before handling the unit.
2) Work in a static-safe environment whenever possible.
3) Do not touch the pins of the I/O connector.
4) Do not disassemble the unit

1.1.2 Suitable Environment

The DC60 has an IP67 environmental rating and can be installed in most industrial environments, including
areas subject to washdown spray and temporary immersion.
The IP67 rating is contingent on the proper installation of the mating connector.

1.1.3 Shaft Loading

A flexible coupler should be used when connecting a DC60 to a drive shaft, because any mismatch in shaft
alignment will result in large radial or axial loading on the shaft of the encoder. Limit shaft loading to the fol-
lowing values. These values statistically yield an L10 life of 2X10
the bearings will have failed after 2X10
The effect is actually cubic. Cutting a shaft load in half will result in an eight fold increase in bearing life.

1.1.4 A Note on Cable Direction

All of the dimensional drawings in the
when using right angle connectors. Use this information to properly route cables when designing the DC60
mounting.

1.2 Availability of CAD Drawings

CAD drawing for all DC60 devices are available on the AMCI website. Direct links to the files are:
http://www.amci.com/downloads/dwg/2D_DC60.zip 
(DWG files compatible with AutoCAD R14+)
http://www.amci.com/downloads/step/3D_DC60.zip 
(AP203 compatible STEP files.)
20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
REQUIRED TASK
P
I
HYSICAL
NSTALLATION
9
revolutions.) Shaft loading has an exponential effect on bearing life.
Radial Load
40 lbs. (178 N)
Table 1.1 DC60 Maximum Shaft Loading Specifications
Outline Drawings
9
revolutions. (Statistically, only 10% of
Axial Load
20 lbs. (88 N)
section (1.3), show the direction that the cable exits
13