Note:
1)
When activated, the high beam LED on device will ash SOS signal in Morse code
format every minute.
2)
Upon activation the device will transmit MOB ACTIVE signal every minute with
Lat/Lon position information. In case the GPS location cannot be updated due to
weather conditions, the last obtained Lat/Log GPS position will be sent.
3)
As AIS MOB is still new on the market, not all chart plotters with AIS show the
correct
icon as recommended by the IMO. As a minimum, they will show the
same icon as used for other craft - normally an
for AIS MOB begins always with 972 which will di erentiate AIS MOB from
normal AIS targets. Please contact with your plotter manufacturer how they
display
on screen when there are further questions.
4)
When the device is mounted in lifejacket, ensure the TB-520 remains out of the
water, as water will inhibit the GPS receiver and may cause di culties obtaining
GPS coordinates.
5)
Ensure that the blue area marked "GPS Area" is not shielded or covered in any
way and always has a clear view of the sky. It is recommended that the Short Test
is performed monthly. Return the TB-520 to a service centre for battery
replacement if battery level is low.
6)
Con rm that the battery expiry date shown is in date for the duration of
intended use.
7)
This product emits low levels of radio frequency energy during operation. Avoid
handling the antenna once activated.
6.1 Battery Life Test
Start the battery life test by using the magnet found on
the back side of the test tab to touch the Test Area for one
full second.
The high beam LED will ash once and the beeper will beep
once signifying the device has entered into battery life test
mode. The green ash indicates that the battery is ok. If
your device ashes red light, this indicates low battery
power and the battery needs to be replaced. The device will
ash 3 times and beep once again to end the test.
6.2 Full Function Test
As illustrated, start the full function test by using the
magnet found on the back side of the test tab to touch the
Test Area. Just like the Battery Test, the strobe LED will ash
once and the device will beep once when the test magnet
approaches the Test Area. Hold the magnet next to the Test
Area for 3 additional seconds in which a second audible
beep indicates the unit is in Full Function Test. The battery
LED and GPS LED will commence to ash every 3 seconds
to indicate the battery status and GPS locating status:
7. Speci cation
APPLICABLE STANDARDS
IEC 60945
EN 303098- 1 V1.2.1
IEC 61108-1
EN 303098- 2 V1.2.1
GPS PERFORMANCE
Receiving Channels
50
Frequency
L1, 1575.42 MHz
Tracking Sensitivity
(-)159 dBm
Reacquisition
(-)159 dBm
Position Accuracy
< 2.0 m SBAS
< 2.5 m Autonomous
VHF PERFORMANCE
Frequency
Data Rate
Tx Power
Bandwidth
Modulation
Range
AIS Message Type
BATTERY
Type
Operating Time
Storage (battery life)
ACTIVATION METHOD
Manual activating or automatic activating with water sensor by immersion
Note: Speci cations are subject to change without prior notice.
. The MMSI number dedicated
- 5 -
- 7 -
ENVIRONMENTAL
Operating Temperature
-20°C~55°C
Storage Temperature
-30°C~70°C
Waterproof
IP68
Immersion Depth (optional)
50m
Compass Safe Distance
0.8m
Explosion Proof (optional)
Ex e m II T6 X
GENERAL/PHYSICAL
Model No.
TB-520
Size
129x52x40mm (L*W*D)
Weight
160 g (main unit only)
AIS 1, 161.975MHz
AIS 2, 162.025 MHz
9,600bps
2W (1W EIRP)
25 KHz
GMSK
4nm typical with receiver antenna > 5m above sea level
Message 1 (UID, GPS position, SOG, COG)
Message 14 (MOB ACTIVE or MOB TEST)
Primary Lithium (not rechargeable)
48 hours at -10°C, typical
5 years, replacement due after emergency use
- 9 -
5. Turning o your TB-520
Insert the activation tab back in the unit and the transmission will be ceased.
When the unit is activated by water sensor, pull the activation tab o and then
reinsert the tab subsequently to turn o the transmission. Put the antenna back
to its original position by wrapping around
the unit, as well as, the antenna cap.
5.1 Closing the red antenna cap
Align the red antenna cap with the unit, longer side facing the front and the
shorter side facing the back. Push the red antenna cap all the way until the
antenna cap clip pass the wedge. The proper tting of the red antenna cap
ensures the water sensors are properly seal from the elements and thus prevent
the unit from being activated when wet.
S/N(UNIQUE ID):
972160001
BATTERY EXPIRY:
JUL 2015
6. Testing your TB-520
The device is equipped with self test capability to perform 2 di erent tests to
ensure the beacon is working perfectly. The rst is a battery life test to check
the beacon's battery power. The second test is a GPS self test that includes
GPS activation and live test message transmission.
The green battery LED indicates that the battery is ok. If the
battery LED ashes red light, this indicates low battery power
and the battery needs to be replaced.
The green GPS LED next to the antenna indicates that GPS x is
achieved, the red GPS LED means that no GPS position is
obtained.
As soon as GPS x is achieved, the device will start sending MOB test messages,
which will be displayed with a
icon on all AIS systems within range. The Full
Function Test will be completed with a beep, after 8 bursts of test messages are
successfully sent. When no valid GPS data is obtained within 5 minutes, the Full
Function Test is regarded as failed and will be ended with a beep as well.
In case of a failed Full Function Test, check and make sure that the antenna is
pointing towards the sky and the "GPS Area" marked on the device is not
obstructed by hand or other objects. When the Full Function Test fails a second
time, return the device to your service center.
Note:
1) You can interrupt the test mode any time by pull o the activation tab and then
insert the tab subsequently. Please notice that under test mode, the device will
not transmit distress message also when the activation tab is removed. Hence
there is no risk of activating the alarm transmission when the user pulls the
activation tab o to abort the test mode.
2) The MOB test message generated by a full function test will appear on all chart
plotters with AIS within range in the form of a SRM (Safe Related Message). The
message is "MOB TEST" with the device´s MMSI number as sender´s identity.
EC Declaration of Conformity
Hereby Alltek Marine Electronics Co declares that this device is in compliance with
the essential requirements R&TTE Directive. All materials, components and
products supplied of the device are in full compliance with RoHS & Weee
directives. A copy of the Declaration of Conformity can be obtained online from
www.alltekmarine.com

RF Exposure warning

Warning: This device generates and radiates RF electromagnetic energy and
requires a Maximum Permissible Exposure of 20cm by operation.
Battery
The lithium-ion battery in TB-520 should be replaced only by AMEC or an AMEC
authorized service provider, and must be recycled or disposed of separately
from household waste. Never attempt to replace the TB-520 battery yourself.
Do not recharge, puncture, deform, short-circuit the lithium batteries contained
in product or put it in re.
The small lithium metal batteries contained in the device can normally be
carried on passenger aircraft in carry-on baggage as a personal item. Always
check with air carrier for any additional restrictions.
End of Life Statement
The symbol above means that your product and/or its battery shall be disposed
of separately from household waste according to local laws and regulations.
S/N(UNIQUE ID):
972160001
BATTERY EXPIRY:
JUL 2015
- 6 -
- 8 -