AMERITRON AL-82 사용 설명서 - 페이지 7
{카테고리_이름} AMERITRON AL-82에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AMERITRON AL-82 16 페이지. Full power
AMERITRON AL-82에 대해서도 마찬가지입니다: 사용 설명서 (16 페이지)
Caution: This page is only valid for transformers that contain these exact color codes for the primary winding. Early
production units did not contain a multiple tap transformer. If the terminal strip has all these color coded wires, then the
unit has the multiple tap transformer.
FILAMENT/BLOWER WIRING INSTRUCTIONS
The AL-82 and 82(X) amplifiers come prewired for 240V line voltage and with the blower prewired for medium high
fan speed. NOTE: The AL-82J Japanese export model is prewired for 208V line voltage and with the blower prewired
for medium high fan speed.. This page gives filament transformer connection details for various line voltages and
blower speeds. The five lug terminal strip and the single lug terminal strip are located immediately behind the ON/OFF
rocker switch inside the unit. The drawing below shows the connection of transformer leads and their purpose.
This chart shows the color code of the transformer leads and their purpose. The number in paren-
thesis indicates the number of the terminal
number three (3) lug is not used to change the filament or blower wiring. Do not add or remove
any wires from the number three (3) lug. Refer to the drawing above. Use the lug numbers above
when referring to both of the Filament connection chart and the Blower connection chart below.
FILAMENT TRANSFORMER LINE VOLTAGE There
are two wires that connect to the terminal lugs which
determine the Filament Line Voltage. The BLACK wire
from the power switch and WHITE wire from rear of the
unit connect to different terminal lugs depending on the
voltage desired. The AL-82 and 82(X) come prewired for
240V operation`. AL-82J comes prewired for 200V
operation". Refer to the chart below. The voltage listed in
the chart below is the maximum line voltage that should be
applied to a given tap. Operation with line voltage in
excess of the tap voltage selected can result in a reduction
of tube life.
* indicates factory shipped (AL-82/X) * *
indicates factory shipped (AL-82)J
that the transformer lead is connected to. The
lug
BLOWER CONNECTIONS
The GREEN and WHITE wires from the rear of the unit
connect to the terminal lugs to control the air speed of the
fan. The AL-82/X/J are prewired for the medium high speed
setting'. Refer to the chart below. The blower connections
can be moved to lower speed taps if air noise is excessive.
Ameritron recommends using the highest speed tap that
noise considerations permit. The lowest speed tap will
develop sufficient air flow for standard amateur SSB and
CW full power operation. The highest speed taps should be
used for contest or RTTY operation.
* indicates factory shipped