Especially for Figure e ,f and g mounting method, the modules may be mounted using
clamps designed for solar modules refer to Figure j, the modules must be supported along
the length of the edge, and should overlap the array rail by 10mm – 14mm
4

Electrical Installation

4.1 Installation Condition
4.1.1 The electrical characteristics are within ±10% of the indicated values of Isc. Voc and
Pmpp under the standard test conditions (irradiance of 1000 W/m
temperature of 25℃.
4.1.2 The IEC & UL standard maximum system voltage for the regular module series is 1000V,
the 1500V standard products are also available according to the requirements. The IEC &
UL standard maximum system voltage for half-cell module series is 1500V (except for
black modules).
4.1.3 Connect quantity of modules that match the voltage specifications of the inverters used in
system. Modules must not be connected together to create a voltage higher than the
permitted maximum system voltage under the lowest local temperature conditions.
4.1.4 Under normal conditions, a photovoltaic module is likely to experience conditions that
produce more current and/or voltage than reported at standard test conditions.
Accordingly, the value of I
when determining component conductor ampacities, fuse sizes, and size of controls
Chint Solar (Zhejiang) Co.,Ltd. | Add:1335 Bin´an Road, Binjiang District, Hangzhou | P.C: 310053
Tel: 0086-571-5603 1888 | Fax: 086-571-5603 2316 | Website: http://energy.chint.com/
Figure h
marked on this module should be multiplied by a factor of 1.25
sc
Figure i
Figure j
2
, AM1.5 spectrum, cell