Canon EOS-1D Mark IV 기능 설명서 - 페이지 6
{카테고리_이름} Canon EOS-1D Mark IV에 대한 기능 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Canon EOS-1D Mark IV 21 페이지. Eos digital slr camera
Canon EOS-1D Mark IV에 대해서도 마찬가지입니다: 포켓 매뉴얼 (2 페이지), 사용 설명서 (19 페이지), 빠른 시작 매뉴얼 (5 페이지), 사용자 설명서 (2 페이지), 브로셔 (35 페이지), 브로셔 (39 페이지), 브로셔 (32 페이지), 빠른 매뉴얼 (2 페이지)
EOS 60D Nomenclature
Hot Shoe
AF Mode Selection Button
Drive Mode Selection Button
ISO Speed setting Button
Metering Mode Selection Button
Main Dial
LCD Panel Illumination Button
Shutter Button
Remote Control Sensor
Red-Eye Reduction/
Self-Timer Lamp
Grip
Battery Compartment
Cover and Release Lever
DC coupler cord hole
Viewfinder Eyepiece
Power Switch
Erase Button
MENU Button
LCD Monitor
Information Button
Playback Button
Top LCD Panel Information
Shots Remaining (
Drive Mode
Shots Remaining During
Single
WB-BKT (
)
Low-Speed Continuous
Self-Timer Countdown (
High-Speed Continuous
Bulb Exposure Time (
10 sec. Self-Timer/Remote Control
2 sec. Self-Timer/Remote Control
ISO Speed
(
AF Mode
Metering Mode
Evaluative
Partial
Spot
Center-Weighted
Highlight Tone Priority
Average Metering
Monochrome
Shooting
Flash Exposure
Compensation
WB Correction/
WB-BKT White
Battery Check
Balance
AEB
Aperture Setting
AF Point Selection (
SD Card Full Warning (
SD Card Error Warning (Card)
Shutter Speed
No SD Card Warning (Card)
(
)
Error Code (
)
FE Lock (
)
Cleaning Image Sensor (
Busy (
)
Built-in Flash Recycling
(
)
214
Built-in Flash/AF-Assist Beam
Flash-Sync Contacts
Mode Dial lock-release button
Lens Release Button
External Microphone IN terminal
HDMI mini OUT terminal
Audio/video OUT/
Remote control terminal (for RS-60E3)
Depth-of-Field Preview Button
Live View Shooting/Video Shooting Button
Dioptric Adjustment Knob
AE Lock/Index/Reduce Button
AF Point Selection/Magnify Button
Quick Control button
SD Card Slot Cover
Quick Control Dial Lock-Release Button
Viewfinder Information
)
AF Point
Spot Metering Circle
)
)
Focusing
Screen
)
AE Lock AEB
*
in-progress
Battery
Check
Focus Confirmation Light
Flash-Ready/
Improper FE Lock
• During One-Shot
Warning
Autofocus: Lights when
focus is achieved, blinks
High-Speed Sync
at 2Hz if focus fails
Indicator (FP Flash)
• During Manual Focus:
(* — FE Lock)
Lights when focus is
Flash Exposure
achieved
Compensation
Maximum Burst (
Remaining Multiple Exposures
Shutter Speed
(
)
White Balance Correction/
FE Lock (
)
Monochrome Shooting
Busy (
)
)
Built-in Flash Recycling
<D+> Highlight Tone Priority
)
(
)
SD Card Full Warning (
)
Exposure Level
SD Card Error Warning (Card)
• Exposure Compensation Amount
No SD Card Warning (Card)
• AEB Range
)
• Red-Eye Reduction Lamp On
Aperture Value (
EOS-1Ds Mark III Custom Function Chart
Nomenclature for EOS 40D
Built-in Flash
Custom
Function Description
Function
Hot Shoe
C.Fn I: Exposure
LCD Panel Illumination Button
E xposure level
1
Metering Mode Selection/White Balance Selector Button
increments
Flash Button
AF Mode Selection/Drive Mode Selection Button
I SO speed setting
ISO Speed/Flash Exposure Comensation Button
2
increments
Mode Dial
Main Dial
Microphone
Strap Mount
3
Set ISO speed range
Shutter Button
4
Bracketing Auto Cancel
Red-Eye Reduction/
5
Bracketing sequence
Self-Timer Lamp
Grip
6
N umber of bracketing shots
Battery Compartment,
S pot metering link
7
Tripod Socket
to AF point
Cover and Release Lever
8
Safety Shift
Dioptric Adjustment Knob
Viewfinder Eyepiece
S elect usable
9
shooting modes
AF Start Button
Print/Share Button
MENU Button
S elect usable
10
metering modes
LCD Monitor
Access Lamp
M etering pattern in Manual
Setting Button
11
mode
INFO Button/Trimming Orientation Button
Quick Control Dial
Multi-Controller
Erase Button
12
Set shutter speed range
Playback Button
JUMP Button
Picture Style Selection Button
13
Set aperture value range
Top LCD Panel Information
Shutter Speed
A pply shooting/
14
Metering mode
(
Busy (
)
F lash sync. speed in
15
Built-in Flash Recycling
Av mode
(
C.Fn II: Image/Flash exp/Display
)
Flash Exposure
L ong exp. noise
1
reduction
Compensation
White Balance
H igh ISO speed
2
noise reduction
Auto
Daylight
3
Highlight tone priority
Shade
Cloudy
4
E-TTL II flash metering
Tungsten Light
5
Shutter curtain sync.
White
Fluorescent
6
Flash firing
Light
Flash
V iewfinder info.
7
Custom
during exp.
Color
L CD panel illumination during
8
Bulb
Temperature
I NFO button when
9
shooting
)
C.Fn III: Autofocus/Drive
1
USM lens electronic MF
2
AI Servo tracking sensitivity
ISO Speed
A I Servo 1st/2nd image
3
priority
Image Recording Quality
4
A I Servo AF tracking method
Battery Check
L ens drive when
5
AF impossible
L ens AF stop button function
Beeper
6
(select Canon Super-telephoto
IS lenses only)
)
Custom Function
Errors and omissions excepted. Custom Functions are subject to change without notice.
Custom
No.
Setting
Function
0
1/3-stop increments
6
(Cont.)
1
Speeds/apertures 1-stop increments, Exposure compensation in 1/3-stops
2
1/2-stop increments
0
ISO set in 1/3-stop increments
1
ISO set in 1-stop increments
7
AF Microadjustment
Disable (camera ISO range 100~3200)
Enable (apply user-registered available ISO range)
A F expansion with
–
Set highest ISO (1-stop increments) up to "H"
8
selected pt
Register
Set lowest ISO (1-stop increments), "L" thru 1600
Return
On (AEB cancels if camera turned off, etc.)
0
9
Selectable AF point
1
Off (AEB remains in effect unless flash turned on)
0
0 – +
10
Switch to registered AF point
1
– 0 +
2
+ 0 –
11
AF point auto selection
0
3 shots
1
2 shots
2
5 shots
A F point display
3
7 shots
12
during focus
0
Disable (spot metering always at center)
1
Enable (spot metering at manually selected AF pt.)
13
AF point brightness
0
Disable
1
Enable (Tv/Av modes)
14
AF-assist beam firing
2
Enable (ISO speed shifts, in P, Tv, Av modes)
Disable (all exposure modes available)
Enable (only modes registered are selectable)
15
Mirror lockup
–
M
P
Register
Tv
BULB
Av
Apply
C ontinuous shooting
16
Disable (all metering patterns available)
speed
Enable (only metering modes registered are selectable)
–
Register
Apply
17
L imit continuous shot count
0
Specified metering mode on camera's LCD panel
1
Evaluative metering only in M mode
2
Partial metering only in M mode
C.Fn IV: Operation/Others
3
Spot metering only in M mode
4
Center-weighted average only in M mode
S hutter button/
1
Disable
AF-ON button
Enable (apply user-registered range)
–
Highest speed: 250–8000
Register
Lowest speed: 30"–60
A F-ON/AE lock
2
button switch
Apply
Disable (use lens's full aperture range)
Q uick Control Dial in
Enable (apply user-registered aperture range)
3
meter
–
Min. aperture (Max. f/): 1.4–91
Register
Max. aperture ((Min. f/): 1.0–64
Viewfinder Information
Apply
Disable (no switching to registered settings)
AF Point
Enable (Press " * " button to switch settings)
AF Point Selection (
)
S ET button when
–
4
With AE lock button (AF on)
shooting
SD Card Full Warning (
)
)
Register
With AE lock button (AF off)
CF Card Error Warning (
)
0
Auto (shutter speed set based on ambient light)
No CF Card Warning (
)
1
1/250 sec.
Focusing
Error Code (
)
T v/Av setting for
5
Screen
Manual exp.
0
Off
Cleaning Image Sensor (
)
1
Auto (camera decides whether to apply reduction)
D ial direction during
Aperture Setting (
)
6
Tv/Av
2
On (noise reduction applied; 1 sec. and longer only)
Shots Remaining (
)
0
Off
7
Av setting without lens
1
On
Shots Remaining During
0
Disable
W B + media/image size
WB-BKT (
)
8
setting
1
Enable
Self-Timer Countdown (
)
*
AE Lock AEB
0
Evaluative flash metering
in-progress
9
Button function
Bulb Exposure Time (
)
1
Average flash metering over all 63 metering zones
0
1st-curtain synchronization
B utton function when
10
WB Correction/
Flash-R eady/
<off>
1
2nd-curtain synchronization (EOS Speedlites only)
Improper FE Lock
WB-BKT White
0
Enable
Warning
Balance
1
Disable – AF assist beam continues to operate
11
Focusing screen
0
Disable
AF Mode
High-Speed Sync
1
Enable (viewfinder info visible during bursts)
Indicator (FP Flash)
0
Off
(* — FE Lock)
1
On during Bulb
0
LCD monitor Displays camera settings
Flash Exposure
12
Timer length for timer
1
LCD monitor Displays shooting functions
Drive Mode
Compensation
Single
0
MF possible after One-shot AF completed
Low-Speed Continuous
CF Card Full Warning
1
Disable after One-shot AF
S hortened release
High-Speed Continuous
(
13
time lag
2
Disable completely in AF mode
Self-Timer (10 sec.)
CF Card Error Warning
–
Slow: -2, -1, 0, +1, +2: Fast
(
Self-Timer (2 sec.)
0
AF priority/2nd shot onward – Tracking priority
No CF Card Warning
AEB
1
AF priority/2nd shot onward – Drive speed priority
A dd aspect ratio
(
Metering Mode
2
Release/2nd shot onward – Drive speed priority
14
information
Evaluative
0
Main focus point priority
1
Continuous AF track priority (ignores closer objects)
Partial
Shutter Speed
0
Focus search on
Spot
(
1
Focus search off
A dd original decision
Center-Weighted Average
FE Lock (
15
data
0
AF stop
Busy (
ISO Speed
1
AF start
L ive View Function exposure
16
Built-in Flash Recycling
(
)
2
AE lock
simulation
(
Monochrome Shooting
Flash-Sync Contacts
Function Description
No.
Setting
3
AF point:M Auto/Auto ctr
Flash Button
4
ONE SHOT AI Servo
5
IS start
6
Switch to registered AF point
0
Disable (no adjustment for front or back-focus)
1
Adjust all by same amount
F orward: -20 ........ 0 ....... +20
Backward
Mode Dial
2
Adjust by lens
0
Disable (one AF point only when manually selected)
1
Enable (expand by adding left/right Assist pts)
Strap Mount
2
Enable (expand by adding ring of six surrounding Assist pts)
0
19 points
1
Inner 9 points
DIGITAL Terminal
Outer 9 points
2
VIDEO OUT Terminal
0
Disable
1
Enable
Lens Release Button
0
direct: disable / : enable
1
direct: disable / : d isable (auto AF select mode impossible to access)
Remote Control Terminal (N3 Type)/
2
direct: enable / : enable
Flash Sync (PC) Terminal
0
On (red illumination on)
1
Off
Depth-of-Field Preview Button
2
On (lights momentarily when focus achieved)
0
Normal
Tripod Socket
1
Brighter
0
Enable (Speedlite's AF assist beam fires normally)
1
Disable
AF Start Button
0
Disable
1
Enable (mirror lowers after each shot)
AE Lock/FE Lock Button/
2
Enable: Down with SET (mirror remains up until SET pressed)
Index/Reduce Button
Disable (shoots at default fps rates)
Enable (applies user-registered fps rates)
–
High speed: 5,4,3,2 fps
Register
Low speed: 1,2,3,4 fps
AF Point Selection/Enlarge Button
Apply
Disable
Enable
Multi-Controller
–
Limited shots: 99–2
Register
Apply
SET Button
CF Card Slot Cover
0
Metering + AF start (at both buttons)
1
Metering + AF start/AF stop
Quick Control Dial
2
Metering start/Meter + AF start (no AF at shutter button)
3
AE lock/Metering + AF start
Access Lamp
4
Metering + AF start/disable (AF-on button)
0
Disable
1
Enable (reverse role of AEL and AF-on buttons)
0
Exposure comp/Aperture
Power Switch
1
AF point selection (instant AF point access with rear dial)
2
ISO speed (instant ISO access with rear dial)
0
Normal (disabled)
1
White balance
2
Image size
Spot Metering Circle
3
ISO Speed
4
Picture Style
Record func. + media/folder
5
6
Menu display
7
Image playback
0
Tv= / Av=
1
Tv= / Av= (reverse functions in M mode for top/rear dials)
0
Normal
1
Reverse direction
0
Disable
1
Enable (possible to set aperture on body w/o lens)
0
Rear LCD panel
1
LCD monitor (displayed when FUNC button pressed)
0
Protect (hold button in: sound rec.)
1
Sound rec. (press & release; protect possible via menu only)
0
Normal (enable)
Focus Confirmation Light
1
Disable , , Multi-controller
• During One-Shot
0
Ec-C IV
Autofocus: Lights when
1
Ec-A, B, C, C II, C III, D, H, I, L
focus is achieved, blinks
2
Ec-S
at 2Hz if focus fails
3
Ec-N, R
• During Manual Focus:
Disable (use camera's built-in settings)
Lights when focus is
Enable (apply user-registered changes)
6 sec. timer: 0–6–59 sec., 1–60 min.
achieved
–
16 sec. timer: 0–16–59 sec., 1–60 min.
Register
Maximum Burst (
)
Time after release: 0–2–59 sec., 1–60 min.
Apply
0
Disable (standard 55ms "time lag")
White Balance Correction
)
1
Enable (as low as 40ms, depending upon lens aperture)
0
Off
ISO Speed (
, )
)
1
Aspect ratio 6:6
2
Aspect ratio 3:4
Monochrome Shooting
)
3
Aspect ratio 4:5
4
Aspect ratio 6:7
Exposure Level
5
Aspect ratio 10:12
• Exposure Compensation Amount
6
Aspect ratio 5:7
)
• AEB Level
0
Off
)
1
• Red-Eye Reduction Lamp On
On (used by optional Original Data Security Kit)
)
0
Disable (LCD auto adjust)
1
Enable (LCD simulates actual exposure level)
Aperture Value (
)
)
215