Baumer GIM500R 매뉴얼 - 페이지 5

{카테고리_이름} Baumer GIM500R에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer GIM500R 20 페이지. Inclination sensors
Baumer GIM500R에 대해서도 마찬가지입니다: 매뉴얼 (29 페이지), 매뉴얼 (13 페이지), 조립 지침 (2 페이지)

Baumer GIM500R 매뉴얼
3

Analog interface communication

3.1 Analog interface properties

• Supply voltage 8...36 VDC
• Sensor is protected against reverse polarity and short circuiting.
• Initialization time after power on ≤ 0.5 s
• Operating current with no load is inferior to 40 mA, at 24 VDC
• Several analog signal outputs 4...20 mA / 0.5...4.5 V / 0...5 V / 0...10 V
• Load resistance ≥1 kΩ / voltage output resp. ≤800 Ω / current output
• Different sensing ranges, 1 and 2 dimensional
• Resolution 12 bit
• Temperature coefficient 0.008 °/K
• Precision: (+25 °C) typical ±0.1°
• Scanning frequency 1600 Hz
• Limit frequency 0.1...25 Hz, 2nd order / deep-pass filter (default: 5 Hz)
• Programmable parameters: preset and offset value resp. filter
• Diagnostic function to identify parameterization errors

3.2 Installation position

The mounting position is of critical importance for the measured signal values. Depending on the mounting
position of the inclination sensor and the movement in the application, the analog signal values will increase
or decrease.

Installation position 1-dimensional

3.2.1
When installing the 1-dimensional inclination sensor, observe the rotation axis shown below is directed in
perpendicular position towards gravity. The maximum misalignment of ±3° must not be exceeded.
The sensor default position is 0° as shown in the illustration below but may be configured at will in a 2-point
teaching or zeroing operation.
Baumer_GIM500R_Analog_MA_EN.docx
11.04.18
5/20
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany