Baumer HMG 10-T-Profibus DP 설치 및 운영 지침 매뉴얼 - 페이지 13

{카테고리_이름} Baumer HMG 10-T-Profibus DP에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer HMG 10-T-Profibus DP 32 페이지. Absolute encoder with magnetic sensing

4.3.3

Version with through hollow shaft

)
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder.
» Lubricate drive shaft!
)
Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
>113 mm
i
The encoder must be mounted with cable connection facing downward and not
exposed to water.
MB246EN - 11171695, 17A2, Baumer_HMG10-ProfibusDP_II_EN
12�
ød (mm)
16
h6
20
h6
10b
10c
MOUNTING / MOUNTING TO DRIVE SHAFT
Loosen the screw
8b
5
10a
10c
10e
10b
10d
1�6x8 mm
Tighten the screw
Mt = 2-3 Nm
section 4.5,
TX 10
8c
9
10b
10c
10 mm
10/29