MOUNTING / DRIVE SIDE MOUNTING OF THE TORqUE ARM
4.4

Drive side mounting of the torque arm

)
Lifetime restrictions and angle error of the encoder
A play of just ±0.03 mm, results in concentricity error of the encoder of 0.06 mm.
That may lead to a large angle error, see
» Mount the torque arm without play.
11/29
section 4.5, page