Baumer Hubner Berlin microGen PMG10 EtherNet/IP 운영 매뉴얼 - 페이지 16
{카테고리_이름} Baumer Hubner Berlin microGen PMG10 EtherNet/IP에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer Hubner Berlin microGen PMG10 EtherNet/IP 40 페이지. Absolute encoder
5
|
Installation
1
Ill. 6: Mounting encoder onto drive shaft
1
Drive shaft
3
M6x20 mm screw for fastening the hous-
ing base (ISO 4017)
5
Housing foot (according to product vari-
ant)
Tools
2.5 mm
n
n
Instruction:
a) Prior to installation, check the drive runout error and dimensions.
b) Mount the encoder in a way ensuring the electrical connection is protected against direct
water ingress.
c) Apply grease onto the drive shaft.
d) Push the encoder coupling onto the shaft of the drive.
e) In doing so, align encoder and drive shaft to minimize parallel offset and angular errors.
f) Mount the encoder to the base using the screws (4x) and washers (4x).
16
5
10 mm
Operating Manual
2
90 mm
2
Coupling
4
Washer B6 for fastening the housing
base (DIN 137)
PMG10 & PMG10P EtherNet/IP | V1
Baumer Hübner
3
4
5