Baumer Hubner Berlin PMG10 설치 및 작동 지침 - 페이지 12

{카테고리_이름} Baumer Hubner Berlin PMG10에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer Hubner Berlin PMG10 32 페이지. Absolute encoder
Baumer Hubner Berlin PMG10에 대해서도 마찬가지입니다: 설치 및 작동 지침 (32 페이지), 운영 매뉴얼 (44 페이지)

Baumer Hubner Berlin PMG10 설치 및 작동 지침
MOUNTING / HOUSING FOOT B3
4.2
Housing foot B3
4.2.1
Mounting the spring disk coupling to the device
We recommend using the Baumer Hübner spring disk coupling K 35, see
page
14, available as accessory� When other couplings are used pay attention to
manufacturer's notes�
7
M
= 1 Nm
t
4.2.2
Mounting to the drive shaft
)
Service life restrictions and angle error by runouts
High runout of the drive shaft can cause device angle error�
High runout of the drive shaft can cause vibrations, which can shorten the ser-
vice life of the device�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The device must be mounted with cable connection facing downward and not
exposed to water�
12/32
2�5 mm
MB261EN - 11196414, 21A1, Baumer_PMG10-Inc_EN_202103_MI_11196414
section 4.3,