8
|
Technical data
Protection class DIN EN 60529
Operating speed
Switching speed range
Operating torque typically.
Rotor torque
Maximum permitted shaft load
Materials
Operating temperature
Relative humidity
Resistance
Corrosion protection
Weight approx.
Connection
I
Programmable product variant only
II
According to product variant
Also see about this
2 Features EtherNet/IP [} 25]
8.1
Blind-hollow shaft dimensions
Ill. 12: Dimensions of blind hollow shaft in mm (unless specified otherwise)
40
14.6
± 9°
~
16
3
A1
A2
A3
L1
L2
111.5
Operating Manual
HMG10
IP66/IP67
≤6000 rpm
ns (off) = ±2 ... ±6000 rpm,
(HMG10P: factory setting 6000 rpm)
10 Ncm
950 gcm
≤ 450 N axial
≤ 650 N radial
Housing: aluminium alloy
Shaft: stainless steel
−40 ...+85 °C
95 % not condensing
IEC 60068-2-6
Vibration 30 g, 10-2000 Hz
IEC 60068-2-27
Shocks 400 g, 1 ms
see data sheet and declaration of conformity
2,2 kg
Bus connection terminal box
Terminal box
86.5
B
ød L1 L2
16 53 65.5
20 35 50
2
II
II
79.5
69.5
66.6
Positive
direction of
± 15°
rotation
HMG10 & HMG10P EtherNet/IP | V1, T1
Baumer Hübner
86.5