ANDI MPK1-12ER-QB6 서비스 매뉴얼 - 페이지 7

{카테고리_이름} ANDI MPK1-12ER-QB6에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ANDI MPK1-12ER-QB6 20 페이지. Room air conditioner

Andi-Co Australia Pty Ltd
ROOM AIRCONDITIONER VOLTAGE LIMITS:
NAMEPLATE RATING
220~240V
PROBLEM
Power failure
No power display
on panel or any one
Transformer (Discharge
of the buttons
transformer before testing)
failure.
Display board or main PCB
failure
Remote control
failure.
Battery failure
Fan motor runs
Cycles on overload.
intermittently
Compressor stops
Refrigerant
instantly after
startup.
Compressor
No power
Water alarm
Power supply cord
Transformer (Discharge
transformer before testing)
Wire disconnected or
Fan motor will not
connection loose
run.
Main PCB failure
Capacitor (Discharge
capacitor before testing)
Will not rotate
MINIMUM
POSSIBLE CAUSE
196V
Check the power supplier if the power supplier is supplied to the
unit. Check the power cord and correct if damaged.
Check resistance between the two input/output lines on
transformer. Replace the transformer if either of the input/output is
open or the transformer is damaged.
Check the voltage on display board. Replace the display board if it
is +5V else replace the main PCB.
Check the voltage of battery. Replace batteries if the voltage is
lower than 2.3V.
Check voltage. Call an electrician if not within limits.
Test capacitor.
Replace if not within +/-10% of manufacture's rating.
Check bearings. Replace the motor if the blower wheel cannot
rotate freely.
Pay attention to any change from high speed to low speed.
Replace the motor if the speed does not change.
The amount of the refrigerant is too much, making the compressor
load too big. Recycle and recharge the refrigerant after checking
for the reason.
The compressor is blocked inside. Replace after checking for the
reason.
Check voltage at electrical outlet. Correct if none.
Check and correct if water alarm happens.
Check voltage at the power cord terminal on Main PCB. Replace
the power cord if none.
Check resistance between the two input/output lines on
transformer. Replace the transformer if either of the input/output is
open or the transformer is damaged.
Connect wire. Refer to wiring diagram for terminal identification.
Repair or replace loose terminal.
Select fan speed and Check the voltage on main PCB. Replace
the main PCB if no voltage in anyone.
Test capacitor.
Replace if not within +/-10% of manufacture's rating. Replace if
shorted, open or damaged.
Fan blower hitting scroll. Realign assembly.
Check fan motor bearings. Replace the motor if motor shaft do not
rotate.
6
Service manual for K1 portable Series
MAXIMUM
253V
REMEDY