Atlas AA50PHD 소유자 매뉴얼 - 페이지 11
{카테고리_이름} Atlas AA50PHD에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlas AA50PHD 20 페이지. 50w mixer amplifier
Atlas AA50PHD에 대해서도 마찬가지입니다: 소유자 매뉴얼 (20 페이지)
AA50PHD-CE
Owner's Manual
50W Mixer Amplifier
Running a Self-Diagnostic Test using the PHD Feature
Step 1 - Install the AAPHD Mixer amplifier, connect the input signals. Turn all levels to minimum. Do not attach the speaker system to
the amp at this point.
Step 2 - Install the 100V distributed speaker system per the design, double check speaker tap settings. The total power for all the
speakers should NOT exceed the maximum power rating of the amplifier installed.
Step 3 - Connect the speaker system to the amplifier. Pay special attention when connecting the speaker leads to the proper terminals
on the amplifier. Note: All speaker power taps must be on a 100V setting.
Step 4 - Turn the amplifier On.
Important: Input levels are to be turn down or off. The Master Level is to be around 12 o'clock position or close to half way up.
Note: If the Master Level is OFF or down the PHD test will not work.
Step 5 - Before starting the system Diagnostic test. Make sure no people are present or near the speakers during the diagnostic test
without taking proper precautions. A 1 watt test tone will be present at each speaker. The audible SPL level will be based on the power
tap setting at each speaker and sensitivity specification of the speaker. The audible SPL level may be alarming to some people. Wear
proper hearing protection before starting the test.
Step 6 - Activate the PHD circuit by inserting a small, pointed tool through the hole on the front panel labeled PHD. Press and hold
the momentary switch for 5 seconds, then release. A test tone will be audible through the speaker system. If the Fault LED does not
illuminate Yellow, the system is properly set up and no errors in the system were found. Continue the installation.
Note: During the initial start of the diagnostic test, the Fault indicator may flash Yellow for a few seconds until an accurate
diagnostic reading has been completed, continue to hold the PHD switch in for 5 seconds to assure the test is complete. After
5 seconds and the Fault indicator is illuminating Yellow steadily, stop and read the section "How to Trouble Shoot Your Speaker
System If the Fault LED is Illuminating.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 11 –
AtlasSound.com
Specifications are subject to change without notice.