Commercial Power Amplifier
Bridge mono Transformer Coupled Output Wiring for 140V/200V Output Operation
The amplifier can be configured to drive 140V and 200V speaker lines.
Please observe all necessary safety precautions as the potential for electric shock at the speaker
terminals is present.
With the amplifier turned OFF, move the rear mounted selector switch to the "Bridge" position and
connect the input signal to channel 1. Connect your speaker load across the "+" terminals of both
output terminals as follows:
• 140V Operation - Connect the positive lead of the speaker load to the channel 1 70V
positive "+" terminal, the negative speaker lead connects to the channel 2 70V positive
"+" terminal. Connect a suitable jumper wire between the two terminals labeled "0".
Consult your local codes to determine if Class I wiring is required (Figure 11).
• 200V Operation - Connect the positive lead of the speaker load to the channel 1 100V
positive "+" terminal, the negative speaker lead connects to the channel 2 100V positive
"+" terminal. Connect a suitable jumper wire between the two terminals labeled "0".
Consult your local codes to determine if Class I wiring is required (Figure 12).
CAuTION: A high voltage potential exists across the two "+" speaker terminals when operating in
any Bridge mode application!
To 140V speaker load
AtlasSound.com
CP400 & CP700
CH-1
8, 4, and 2 Ohms
CP700
D I R . O U T P U T
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
BRIDGE
350 W / 70.7 V
MONO
CH-2
8, 4, and 2 Ohms
D I R . O U T P U T
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
BRIDGE
MONO
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Specifications are subject to change without notice.
LIMIT
LIMIT
SIGNAL
SIGNAL
CH-1
CH-2
AUDIO TRANSFORMER
+
-
0
70
100
-
+
-
+
+
70V
25V
- 100V +
AUDIO TRANSFORMER
+
-
0
70
100
-
+
-
+
-
70V
25V
- 100V +
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS RISQUE DE CHOC ELECTRIQUE
Telephone: 800.876.3333 • Fax: 800.765.3435
– 13 –
Owner's Manual
CH-1
I S O L . O U T P U T
Note Jumper
CH-2
I S O L . O U T P U T
Figure 11
MADE IN CHINA
NE PAS OUVRIR