Annovi Reverberi RSV Series 사용 설명서 및 부품 설명서 - 페이지 9
{카테고리_이름} Annovi Reverberi RSV Series에 대한 사용 설명서 및 부품 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Annovi Reverberi RSV Series 16 페이지. Plunger pumps
Operating Instructions and Parts Manual
Plunger Pumps
Service Pumps (continued)
Unloader Adjusting Instructions
Follow these easy steps to adjust the
pressure:
1.
Loosen nut (pos. #3) with 10mm
wrench.
2.
Turn brass (pos. #4) clockwise until
it stops.
3.
Start pump, watch pressure gauge
and turn (pos. #2) using 3mm hex
clockwise until recommended/rated
pressure is obtained. Line pressure
will be approximately 200 psi less
then actual head pressure. DO NOT
set line pressure to rated.
4.
Release trigger and make sure there
is minimal spike (200-300 psi) (Re-
peat this step two or three times).
5.
Tighten nut (pos. #3) down against
(pos. #4).