Figure 6. Wiring SYL-1813-MR with an EGT probe and an alarm buzzer.
E.2 Pressure transducers
Here is a brief description of how to set up the gauge for reading an Auber-103,
3 Bar MAP Sensor.
a) Identify the power, signal, and ground wires on the pressure sender (please
refer to the manual of pressure sender). Connecting power cable to terminal 10,
signal cable to terminal 9, and ground cable to terminal 6.
b) To display the pressure in bar (with 0.01 bar resolution), enter the Basic
Parameter Setting Mode using access code 0089, change the input type Inty to
"5v" input (5v), then set dot = 00.00, PuL = 00.01, and PuH = 03.15.
c) To display the pressure in PSI (with 0.1 PSI resolution), enter the Basic
Parameter Setting Mode with access code 0089, change the input type Inty to
"5v" input (5V), then set dot = 000.0, PuL = 000.2, and PuH = 045.7.
E.3 Water/oil temperature sensor
If a VDO 150° C/300° F sender is used to read water/oil temperature, here is the
basic settings.
a) Connect the VDO sender to terminal 8; jump a wire between terminal 6 and 7;
jump another wire between terminal 2 and 6.
b) Enter the Basic Parameter Setting Mode using code 0089; set input type
Inty = vdo; and set CorF to "C" or "F" for desired temperature unit.
Auber Instruments Inc.
5755 North Point Parkway, Suite 99,
Alpharetta, GA 30022
www.auberins.com
Tel: 770-569-8420
Copyright © 2021 Auber Instruments Inc. All rights reserved.
No part of this datasheet shall be copied, reproduced, or transmitted in any
way without the prior, written consent of Auber Instruments. Auber Instruments
retains the exclusive rights to all information included in this document.
2021.05
Power
12VDC
-
+
4
3
2
1
9
8
7
6
+ TC -
WWW.AUBERINS.COM
P3/3