Cable connection(DMX)
Use a cableconforming to specifications EIA RS-485: 2-poletwisted, shielded, 120Ohm characteristic impedance,
22-24AWG,low capacity. Do not use microphone cable or other cable withcharacteristics differing from those
specified. The end connections must be made using XLR type 3 or 5-pin male/female connectors. A terminating
plugmust be inserted intothelastprojector witha resistance of 120Ohm (minimum 1/4W)between terminals 2
and3.
IMPORTANT: Thewiresmustnot makecontact witheachotheror withthe metalcasing of the connectors.
The casing
itself must be connected
connectors.
Rigging (Optional)
This equipment can be positioned and fixed by clamp in every direction of the stage. Locking
system makes it easy to fasten to the bracket.
Attention! Two clamps is needed to fix the equipment. Every clamp is locked by fastener of 1/4
kind. Fastener can only be locked clockwise.
Attention! Fasten a safety string to the additional hole of side aluminum piece. The secondary
accessory can not hang on the delivery handle. Nip the equipment on bracket.
Check if rigging clamp (not including the one inside) damaged or not? If stand ten times
weight as the equipment. Make sure the architecture can stand ten times weight as all the
equipments, clamps, wirings and other additional fixtures.
Screws for clamping must be fixed firmly. Take one M12 screw (Grade 8.8 or higher) to clamp
bracket, and then screw the nuts.
Level the two hanging points at the bottom of clamp. Insert fastener to the bottom, lock the
two levers by 1/4 rotating clockwise; then install another clamp.
Install on safety string which stands at least ten times weight as equipment. Terminal of the
accessory is designed for clamps.
Make sure pan/tilt lock unlocked or not. Keep the distance more than 1M from equipment
to flammable material or lighting source.
to the
shield braid and to pin 1 of the
Figure 1 DMX Cable connection