Operating Instructions
(1) Power on to enter the standby state. Atomization starts when there is water.
(2) When atomization is turned on, the fan is simultaneously turned on. When
atomization is turned off, the fan is simultaneously turned off.
(3) Water shortage protection: when the water level is 2mm below the metal probe head,
atomization will be turned off; when the water level is 2mm above the metal probe
head, atomization will be turned on again;
(4) The input and output characteristics of Wire NO.3 (orange), NO.4 (red), and NO.6
(black) can be changed according to requirements.
(5) This atomizing module cannot operate in parallel with each other in a common water
tank.
Precautions:
(1) Clean the transducer periodically to avoid incrustation
(2) The fragile atomizer could be damaged by strong vibration or impact. So please
install carefully.
(3) The operating temperature is 3℃-50℃. It is recommended to operate at over 25℃.
Smart Atomizer UM0077