Section 4: SYSTEM OPERATION
–––––––––––––––––––––––––––– USER ACCESS CODES –––––––––––––––––––––––––––

Adding a Secondary User Code

MASTER CODE + [CODE KEY] + USER # ( 2, 3, OR 4) + DESIRED 4-DIGIT ACCESS CODE.
(The system will emit a single beep when a secondary code has been successfully entered.)

Deleting a Secondary User Code

MASTER CODE + [CODE KEY] + USER # (2, 3 OR 4)
Notes:
All Master and Secondary security codes permit access to the system for arming, disarming, etc.
If a secondary code is inadvertently repeated for different users, the lower user number will take
priority.
Opening and closing reports are sent for the Master as No. 1. User codes are sent as
and 4, respectively.
––––––––––––––––––––––––––– KEYPAD FUNCTIONS –––––––––––––––––––––––––––

System Commands

Before arming, the system must be in the READY condition (all zones must be intact). If the "NOT
READY" message appears, press the
MODE
AWAY
STAY
INSTANT
MAXIMUM
DISARM
BYPASS
QUICK BYPASS
(if enabled)
CHIME MODE
SITE-INITIATED
DOWNLOAD*
* Initiates phone call to the downloading facility.

Panic Keys

A panic function is activated when:
• Both keys of the appropriate key pair are pressed at the same time, or
• The appropriate lettered key is pressed for at least 2 seconds.
The panic functions are identified by the system as follows:
Keys
Displayed as Zone
[1] & [ * ], or [A]
95
[ * ] & [#], or [B]
7
[3] & [#], or [C]
96

Keyswitch LED Indications

RED
MEANING
OFF
DISARMED & NOT READY
SLOW FLASH
ARMED READY
RAPID FLASH
ARMED
READY [ * ] key to display faulted zones.
SUMMARY OF SYSTEM COMMANDS
HOW TO PERFORM
Security Code + [2]
Security Code + [3]
Security Code + [7]
Security Code + [4]
Security Code + [1]
Security Code + [6] +
Zone #(s)
Security Code + [6]
Security Code + [9]
(toggles on and off)
Security Code + [#] + [1]
Zone Type
24-Hr. Silent
Programmable (24-Hr.
Silent, Audible,
Auxiliary, or Fire
24-Hr. Audible
EXIT DELAY
ENTRYDELAY
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Notes:
• Keys [A], [B], [C] are not on all keypads.
• Key [D], if present, is not active here.

Keyswitch Operation

• To arm AWAY, turn key and release within a 1/2 second.
• To arm STAY, turn and hold key for longer than 2 seconds.
• To disarm, turn key and immediately release.
-10-
Numbers 2, 3,
PERIMETER
INTERIOR ARMED
ARMED
Yes
Yes
Yes
No
Yes
No
Yes
Yes