Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.
Field
Function
SYSTEM SETUP (
20–
29)
20
DEALER INSTALLER CODE
21
QUICK ARM ENABLE
22
RF JAM OPTION
23
QUICK (FORCED) BYPASS
24
RF HOUSE ID CODE
26
CHIME BY ZONE
27
POWERLINE CARRIER DEVICE (X–10)
HOUSE CODE
28
ACCESS CODE FOR
PHONE MODULE
29
LONG RANGE RADIO OUTPUT
ZONE SOUNDS AND TIMING (
31
SINGLE ALARM SOUNDING per ZONE
32
FIRE ALARM SOUNDER TIMEOUT
33
ALARM SOUNDER (BELL) TIMEOUT
34
EXIT DELAY
35
ENTRY DELAY #1 (zone type 01)
36
ENTRY DELAY #2 (zone type 02)
37
AUDIBLE EXIT WARNING
38
CONFIRMATION OF ARMING DING
39
POWER UP IN PREVIOUS STATE
DIALER PROGRAMMING (
Do not fill unused spaces. Enter 0–9; #+11 for '
field by pressing [
]. The next data field number is displayed.
40
PABX ACCESS CODE
41
PRIMARY PHONE No.
42
SECOND PHONE No.

PROGRAMMING FORM

Data Entries
|
|
|
31 –
39)
|
|
|
40 –
42)
'; #+12 for '#'; #+13 for a 2-second pause. If fewer than the maximum digits entered, exit the
|
used, enter "∗ (#+11) 70" plus "# + 13" (pause).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Enter up to 20 digits. To clear entries, press
NOTE: These phone number fields cannot be edited by the Dealer Installer Code after the panel is locked.
Programmable Values
4 digits, 0–9
|
|
[4112]
Can perform all system functions except, after the panel
is locked, cannot edit the reporting phone numbers
(fields *41, *42); panel is locked after initial upload.
0 = no; 1 = yes
[1]
0 = no RF Jam detection; 1 = send RF Jam report
[0]
UL: must be 1 if wireless devices are used
0 = no quick bypass UL: must be "0"
[0]
1 = allow quick bypass (code + [6] + [#] )
00 = disable all wireless keypad usage
[0,0]
01–31 = using 5827, 5827BD or 5804BD keypad
[00,00,00]
0 = no; 1 = yes (select zones to chime on zone list 3,
[0]
using *81 Menu mode)
0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G,
[0]
7 = H, 8 = I, 9 = J, #10 = K, #11 = L, #12 = M, #13 = N,
#14 = O, #15 = P UL: not for fire or UL installations
00 = disable; 1st digit: enter 1–9; 2nd digit: enter # + 11
[00]
for "
", or # + 12 for "#".
UL: must be "00" for UL Commercial Burg. installations
0 = disable; 1 = enable
[0]
0 = no UL: must be "0"; 1 = yes
[0]
0 = sounder stops at timeout;
[1]
1 = no sounder timeout UL: must be "1" for fire install.
0 = none; 1 = 4 min; 2 = 8 min; 3 =12 min; 4 = 16 min;
[1]
UL: For residential fire alarm installation, must be set for a
minimum of 4 min (option 1); for UL Commercial Burglary
installations, must be minimum 16 min (option 4)
00 - 96 = 0 - 96 secs; 97 = 120 secs
[60]
SIA Installations: minimum exit delay is 45 seconds
UL: see inst. instr. for requirements.
00 - 96 = 0 - 96 seconds
[30]
97 = 120 seconds
98 = 180 seconds
99 = 240 seconds
For UL Residential Burglary Alarm installations, must be set
for a maximum of 30 seconds; entry delay plus dial delay
should not exceed 1 min. For UL Commercial Burglar Alarm,
total entry delay may not exceed 45 seconds.
See *35 Entry Delay 1 above for entries.
[30]
0 = no; 1 = yes
[1]
SIA Installations: must be enabled (enter 1)
0 = no; 1 = yes (wired keypads and RF)
[0]
2 = yes, RF only
UL: must be "1" for UL Commercial Burglar Alarm inst.
0 = no; 1 = yes UL: must be "1"
[1]
Enter up to 6 digits. To clear entries, press
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
41
or
42
– 3 –
SIA Installations:
minimum entry delay is
30 seconds
40
|
|
|
|
|
|
respectively .
. If call waiting