FIRE & BURGLARY COMMON FEATURES
VIEWING CENTRAL STATION MESSAGES
Users of the system may periodically
receive messages on their display screens
from their monitoring agency or installer.
When a message is waiting to be viewed,
the message shown below will appear.
MESSAGE. PRESS 0
FOR 5 SECS.
PANIC KEYS
(FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS)
There are three possible combinations of
paired keys that are installer programmable
emergency functions. See your installer for
the functions that have been programmed
for these emergency key pairs. Typical
functions that might be programmed are
Silent Police, Audible Police, Personal
Emergency, and Fire.
To use a Panic function, simply press
both keys of the assigned pair at the
same time and hold down for at least
two seconds .
PANIC KEY FUNCTIONS:
(Fill-in box for panic function)
KEY [*] + [#] (zone 99)
KEY [*] + [1] (zone 95)
KEY [#] + [3] (zone 96)
– 18 –
Press and hold down the [0] key for 5
seconds
to
display
the
message
transmitted to you. The message could
take up to four screens to display all the
information available.
RESULT
If programmed for silent emergency by your
installer, and the system is connected to a
central alarm monitoring station, the police
emergency key press will send a silent
alarm signal to the central station, but there
will be no audible alarms or visual displays.
If programmed for audible emergency by
your installer, a loud, steady alarm will
sound at your console and at any external
sounders that may be connected [ ALARM
plus a description would also be displayed.
A personal emergency alarm key press will
notify the central station (if connected) and
will sound at Consoles, but not at external
bells or sirens.
A fire alarm key press will send a fire alarm
message to the central station and will
uniquely sound external bells and sirens
(FIRE plus a description would also be
displayed).
FIRE & BURGLARY COMMON FEATURES
ADDING, CHANGING AND DELETING USER CODES
The system allows up to 99 4-digit user codes to be programmed. When programmed,
each code is assigned an authority level which determines the system functions that code
can perform. There are six authority levels as listed in the table below. Aside from your
installer who programs codes at installation time, the system allows master and manager
level users to program codes on an "as needed" basis, for use by those who need limited
and/or temporary control over system operation.
Level/Title
Arm/Disarm
Silence
Burglary
Alarms, Supv
System
& Trouble
1-Master
yes
yes
2-Manager
yes
yes
3-Operator A
yes
yes
4-Operator B
yes
yes
5-Operator C
yes, can disarm
yes
only if used to arm
6-Duress
yes, sends silent
yes
panic report
General Rules on Authority Levels and changes
•
A master or manager user may only
add, delete or change users to/from a
lower authority level (i.e. a master can
assign a lower level user code, but
cannot assign another master code).
•
Each user is assigned a 2-digit user
number (single digit user numbers must
be preceded by a "0". Ex. 03, 04, etc.), a
4-digit user code and an authority level.
IMPORTANT!: During user edit mode, all consoles except the one being used will display
"User Edit Mode – Please Stand By", and key depressions (except Panic) at those consoles
will be ignored. Panic key depressions will cause an alarm and terminate user entry. To exit
User Edit Mode, press either [*] or [#], or don't press any key for 10 secs.
To Add a User:
1. Enter Master or Manager code.
2. Depress CODE [8] key.
3. Enter a new 2-digit User Number.
4. Enter 4-digit code for that User Number.
5. The Console will prompt for the authority
level for this user Enter a number (1-6
from table).
6. The console will display the user
number and corresponding authority
level.
To Delete a User:
1. Enter Master or Manager code.
2. Depress CODE [8] key.
3. Enter User Number to be eliminated.
4. Enter Master or Manager code first
entered.
Add/Change
Bypass
Activate Test
Security
Zones
Modes
Codes
yes, levels 2-6
yes, burg
yes, burg.
only
zones (and fire
walk test, fire
zones if
drill
enabled)
yes, levels 3-6
yes, burg
yes, burg.
only
zones only
walk test
no
yes, burglary
no
zones only
no
no
no
no
no
no
no
no
no
•
The only way to assign a user's
authority level is by using the "Add A
User" procedure described later.
•
Before assigning a code, be sure it does
not conflict with the DURESS code.
•
You may view your authority level by
entering your user code + [*] + [*].
5. The system will recognize that the User
number is already in use and will prompt
whether or not it should be deleted.
Press 0 (NO) or 1 (YES). If yes, the
system will delete the authority level and
all other information about that user.
To Change a User's Code:
1. Enter Master or Manager code.
2. Depress CODE [8] key.
3. Enter the user number to have its code
changed.
4. Enter the new 4-digit code for that user.
5. The system will recognize that the user
is already in use and will prompt
whether or not this is a new user. Press
0 (NO). The system will confirm that the
change
is
allowed
based
authorization level, and if so, puts the
new code into effect.
– 19 –
on