ADEMCO VISTA-20SE 프로그래밍 양식 - 페이지 4

{카테고리_이름} ADEMCO VISTA-20SE에 대한 프로그래밍 양식을 온라인으로 검색하거나 PDF를 다운로드하세요. ADEMCO VISTA-20SE 8 페이지. 2-partitioned security system
ADEMCO VISTA-20SE에 대해서도 마찬가지입니다: 사용자 설명서 (4 페이지), 사용자 설명서 (9 페이지), 프로그래밍 양식 (8 페이지)

ADEMCO VISTA-20SE 프로그래밍 양식
* 49
SPLIT/DUAL REPORTING
** A 10-digit code is sent to the pager consisting
of a 4-digit subscriber number, a 3-digit event code,
and a 3-digit user or zone number.
See Installation Instructions for an explanation
of the 10-digit code.
* Ca n o n l y b e u s e d i f p r i ma r y r e p o r t i n g f o r ma t i s A d e mc o Co n t a c t I D.
* 50
15 SEC DIALER DELAY (BURG)
* 51
PERIODIC TEST REPORT
* 52
TEST REPORT OFFSET
* 53
SESCOA/RADIONICS SELECT
† Entry of a number other than one specified will give unpredictable results.
* 56
ZONE ASSIGNMENT/ALARM REPORT CODES —This field is an interactive mode. Fill in the required
data on the worksheet below (and on next page) and follow the programming procedure in the installation
manual.
ZONES ON CONTROL:
ZONE
RESPONSE
DESCRIPTION
Wired Zone 1*
Wired Zone 2
Wired Zone 3
Wired Zone 4
Wired Zone 5
Wired Zone 6
Wired Zone 7
Wired Zone 8**
Expansion Module
Supervision
Duress
Console Panic (1 &
Console Panic (3 & #, or C)
Console Panic (
& #, or B)
*
*
Zone 1 can be used as a 2-wire Fire zone.
0 = Disable (Backup report only)
TO PRIMARY PHONE No.
1 = Alarms, Restore, Cancel
2 = All except Open/Close, Test
3 = Alarms, Restore, Cancel
4 = All except Open/Close, Test
5 = A l l
TO PRIMARY PHONE No.
6 = All except Open/Close
7 = All reports
8 = All reports
9 = All except Open/Close
0 = no; 1 = yes; "0" for UL installations
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days (Enter Test
Code in field * 64. Reports with Partition 1 subscriber No.)
0 = 24 hour; 1 = 6 hours; 2 = 12 hours; 3 = 18 hours (Time to 1st
report from programming or downloading).
0 = Radionics (0–9, B–F reporting); 1 = SESCOA (0–9 only
reporting). Select 0 for all other formats.
ZONE
No.
(Zn)
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
9
9
2
or A)
9
5
*,
9
6
9
9
**
Zone 8 can be used as a Glassbreak zone.
[0]
† [0]
† [0]
† [2]
[0]
See explanation of headings on next page ·
ZONE
PART'N ALARM RPT CODE
TYPE
No.
(ZT)
(P)
0
5
Both
Both
— —
Both
Both
Both
– 4 –
TO SECONDARY PHONE No.
Others
Open/Close, Test
A l l
A l l
A l l
TO PAGING No. * (Secondary)
** Alarms, Open/Close, Troubles
** Alarms, Troubles
* * Alarms, Open/Close, Troubles
* * A l a r ms , O p e n / Cl o s e f o r
u s e r s 5 - 2 5 ( u s e r s 5 - 1 6 o r
wi r e l e s s b u t t o n z o n e s 1 0 -
2 5 ) , Tr o u b l e s
INPUT
(Hex)
TYPE
(RC)
(In)
HW
HW
HW
HW
HW
HW
HW
HW
Ñ
Ñ
Ñ
Ñ
Ñ
TIME
(RT)
Ñ
Ñ
Ñ
Ñ
Ñ