ADEMCO 651-12EX 설치 지침 매뉴얼 - 페이지 11
{카테고리_이름} ADEMCO 651-12EX에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ADEMCO 651-12EX 18 페이지. Passive infrared motion detectors
Diagram 10 shows typical sources of switched positive (+) control voltage signal. Note that some controls
permit direct connection to the detector and others require a No. 638 (or 63312) Opening/Closing Switching
Module to be used between the control and the detector.
Note also that AC Powered detectors (Nos. 650,651) may obtain DC control signals from 12 volt controls as
well as from 6 volt controls.
Options:
The options are programmed by making the proper CONTROL SIGNAL connection(s) and cutting the colored
jumper(s) on the PC board. See Diagram 6 or 9 for locations and Diagram 11 for summaries of the options.
CAUTION: Any jumper that is cut must have Its loose ends taped (or othemise insulated) to prevent accidental
electrical contact with other points.
1. Day Relay Disable Only Option (Nos. 659,656-6,651,651-6 only): In this mode, the LED and detector relay re-
main active during the ARMED period, but during the DISARMED period, only the LED remains active. The
relay is silent and inactive (remains locked in). TO SELECT: ONLY PROPER CONTROL SIGNAL VOLTAGE IS
REQUIRED. DO NOT CUT ANY JUMPERS.
2 Night LED Disable Option (all units): In this mode the LED (and any remote LED) will be Inactive (remain
OFF) during the ARMED period and active (indicate when motion is being detected) during the DISARMED
period. During the DISARMED period the relay will be silent and inactive (remain locked in) on Nos. 656,
650-6,651,651-6 only. TO SELECT: Nos. 650,6566,651,651-6: CUT THE GREEN JUMPER. Nos. 65612EX,
651-12EX:'ONLY PROPER CONTROL SIGNAL VOLTAGE IS REQUIRED.
3. intrusion Memory Option (all units): in this mode the LED(s) will be inactive during the ARMED period but
should an intrusion occur in the protected area, the alarm relay will transfer and this fact will be stored in
the detector's memory. When the system is DISARMED, the LED on any detector which had signaled and
stored an alarm will light and remain lit until cleared. The LED memory can be cleared by momentartiy ARM-
ING and then DISARMING the system. The LED(s) will then respond ON and OFF normally to motion
detected in the protected area during the DISARMED period. During the DISARMED period the relay will be
silent and inactive (remain locked in) on Nos. 650,650-6,651,651-6 only. TO SELECT: Nos. 650,650-6,651,
651-6: CUT THE RED AND GREEN JUMPERS. Nos. 65612EX. 651;12EX: CUT THE RED JUMPER.
Note: With a No. 1000,1003,1005 or 1020 Deluxe Control: During disarming, when the panel's keyswitch is
turned from ON (ARMED) to CIRCUIT TEST, the LED on any detector which had signaled and stored
an alarm will light. A pause at CIRCUIT TEST with permit examination of each detector for such an in-
trusion memory indication. Turning the keyswitch through BELL TEST to OFF wlii clear the LED
memory and disarm the system.
ADJUSTMENT AND TESTING:
I
IMPORTANT: Wait at least two minutes after connecting
power before attempting to walk-test tne unit.
I
Alignment:
The adjustment and testing of the detector should be conducted with the protected area cleared of all people.
In some business establishments it will be more convenient to do this after hours. The protective system's
control should be OFF during the procedure to prevent unwanted alarms from being sounded.
The alignment of the zones in the horizontal direction may be determined precisely by using the Zone Locator
LED provided, as described next. Note: The Zone Locator light should not be used for vertical alignment.
Follow the recommended mounting height vs. range Diagrams 3 and 5 for this purpose.
To use the Zone Locator LED, remove the small blue dot sticker from the front of the detector's optical head
and insert the screw provided with the Zone Locator LED in the threaded hole found behind the sticker. Fit the
LED atop the raised portion in front of the casting so that the LED fits into the groove provided, with the
ground lug under the screw to secure the assembly. Connect the LED lead to terminal 1 of the detector. With
ower applied to the unit and the cover off, the LED's steady red light can be seen reflected in the facets of
he unit's reflector mirror surface by an observer, about 10 feet (3Om) away, looking back at the unit from each
of protection. The red light will be in view below eac&zone's actual lower boundary, displace vertically
'77