5817CB
PRIMARY LOOP OPTIONS TABLE
SWITCH
SETTING
1
REPEATING
ON
TRANSMISSION
(every 4 sec.)
UPON PRIMARY
LOOP FAULT
Use for high priority
alarm, such as fire.
SINGLE
OFF
TRANSMISSION
PER PRIMARY
LOOP CHANGE-
OF-STATE
Notes:
a. In order for the control panel to enroll the transmitter, the DIP
switches must be Set to OFF-ON-ON-OFF (see Diagram 2).
b. The auxiliary loops are not affected by the DIP switch settings.
WIRING CONNECTIONS
Connect the loop wiring to the unit's terminals before installing the battery (see Diagram 2).
Notes:
a. Primary loop 1 is a supervised loop and must have an end-of-line (EOL) resistor
(470K ohms, supplied) placed across the sensor. Additionally, for primary loop 1,
a contact device may not be installed more than 20 feet from the transmitter.
b. If loop 2 is not going to be used, the magnet is not necessary.
c. If loop 3 is not going to be used, no connection is needed across its terminals.
For UL household burglary and fire installations, the loop 3 contact device
(if used) may not be more than 3 feet from the transmitter.
SPECIFICATIONS:
Dimensions
• 1-9/16"W x 3-1/2"H x 1-3/16"D (40mm x 89mm x 30mm)
• Battery 3v Lithium (see BATTERY INSTALLATION AND REPLACEMENT).
UL Listings
Commercial Fire . . . . . . . . . . .UL864
Household Fire . . . . . . . . . . . .UL985
Household Burg . . . . . . . . . . .UL1023
Commercial Burg . . . . . . . . . .UL365,UL609,UL1076,UL1610
Diagram 2. Transmitter, Cover Removed
ORDERING:
Part No.
Description
5817CB
Wireless Commercial/Household Transmitter
L/5817CB/D
4/01
DIP SWITCH POSITION
2
3
SWITCH MUST
SWITCH MUST
ALWAYS BE
ALWAYS BE
IN THE
IN THE
ON
ON
POSITION
POSITION
4
SWITCH MUST
ALWAYS BE
IN THE
OFF
POSITION
MOUNTING
PLATE
CASE
HOLE
HOLDING
POSTS
TAMPER SWITCH
HOLD DOWN
MOUNTING
PLATE HOLES
CONCEALED
WIRING
ENTRY
HOLE
LOCKING
TAB
Diagram 1. Mounting Plate
Note: For UL commercial and
household fire installations, only
one initiating device may be
connected to this transmitter.
For UL commercial burglary
installations, multiple initiating
devices may be used as long as
the devices all service the same
function such as door/window
contacts, motion or glassbreak
detectors. All initiating devices
must be located within the
same room.
Wireless
Commercial
Transmitter
5817CB-001-V0
165 Eileen Way, Syosset, NY 11791
Copyright ©2002 Pittway Corporation
ADEMCO is an ISO9001 Registered