Autonics BD-065 매뉴얼 - 페이지 7
{카테고리_이름} Autonics BD-065에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Autonics BD-065 14 페이지. Laser displacement sensors
Autonics BD-065에 대해서도 마찬가지입니다: 제품 설명서 (6 페이지), 제품 설명서 (5 페이지)
BD Series
▣ Mounting Location
Select mounting location regarding displacement of the object, reference distance and measurement range.
Mount sensor head where the object is located at the reference distance by checking the operation of indicators
and displacement value.
◎ Indicator display
Check the operation of indicators to know distance between sensor head and the object.
NEAR indicator (green)
FAR indicator (green)
Power indicator (red)
Laser emission indicator (green)
• NEAR/FAR indicators turn on, off and cross-flashing by the distance between the sensor head and the object and the indicator
are on both, it means the sensor head is located in optimum area near reference distance.
• Power indicator is on when power is supplied.
• Laser emission indicator is on during laser emission.
※The linearity guaranteed measurement range.
◎ Displacement indication
Reference
distance
◎ Indication by distance
Rated
Reference
Model
measurement
distance
range
BD-030 30
25 to 35
BD-065 65
55 to 75
BD-100 100
80 to 120
※The linearity guaranteed measurement range.
E-12
Distance between
the sensor head
and the object
The value is displaced more positive (+) as the object is closer to sensor head,
more negative value (-) as the object is far from sensor head relative to the origin (0).
(+)
(0)
Rated measurement range
(-)
Indication
NEAR ON
※
25 to 31
55 to 67
80 to 104
Rated measurement range
※
Reference
Reference distance±
distance
( Rated measurement range×10%)
※
(unit: mm)
NEAR/FAR ON
FAR ON
29 to 31
29 to 35
63 to 67
63 to 75
96 to 104
96 to 120
OFF
ON
Cross-
flashing