Autonics BF4R-R 매뉴얼 - 페이지 5

{카테고리_이름} Autonics BF4R-R에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Autonics BF4R-R 8 페이지. Fiber optic amplifier
Autonics BF4R-R에 대해서도 마찬가지입니다: 사용 설명서 (8 페이지), 매뉴얼 (11 페이지), 매뉴얼 (7 페이지)

Autonics BF4R-R 매뉴얼

Mode Setting

Sensitivity setting
Light ON
Press the [ON]
button at light ON
Press the [OFF]
button at light OFF
The stability indicator [STAB] flashes once
when the difference of sensitivity between
ON and OFF is enough. (flashes 5 times
when the difference is not enough)

Sensitivity Adjustment

Before sensitivity setting, install the fiber optic cable.
After completing the setting, do not move or bend the fiber optic cable. If not, it may cause incorrect detection.
Adjustment by the sensitivity setting button (common)
● Light ON
The control output turns on at Light ON status and turns off
at Light OFF status.
Order Setting method
Mount the fiber optic cable within sensing distance.
Change the mode setting switch to [SET].
Diffuse reflective: Press the [ON] button with a sensing target.
Through-beam: Press the [ON] button without a sensing target.
<Diffuse reflective >
Mark
(Low reflectance)
Background
reflectance)
Light ON
The stability indicator [STAB] (green) flashes
at ON state. (check the target position)
Diffuse reflective: Press the [OFF] button without a sensing target.
Through-beam: Press the [OFF] button with a sensing target.
<Diffuse reflective >
Mark(Low
reflectance)
Background
reflectance)
Light OFF
• When there is enough sensitivity difference between ON state
and OFF state, the stability indicator [STAB] flashes one time
only at stable sensing level.
• When there is not enough sensitivity difference between ON
state and OFF state, the stability indicator [STAB] flashes five
times at unstable sensing level.
※ The sensitivity can be set at unstable sensing area.
Change the mode selection switch to [LOCK] to
fix the set sensitivity. Even though the sensitivity
setting button is touched, setting sensitivity shall
not be changed.
※ When the power is OFF, the set sensitivity is saved.
Change the mode setting switch to [SET]
Dark ON
Press the [OFF]
button at light ON
Press the [ON]
button at light OFF
Set the mode setting switch to [LOCK]. (completes setting)
<Through- beam>
(High
Light ON
<Through- beam>
(High
Light OFF
Fiber Optic Amplifier
SET
LOCK
Set/Relase the interference prevention function
Press [ON]+[OFF] at the same time for 2 sec.
The stability indicator [STAB] flashes continuously
Set the interference
prevention function
Frequency 1
Press the [ON]
Press the [OFF]
button
button
(Frequency 1,
(Frequency 2,
response time
response time
: max. 0.5ms)
: max. 0.7ms)
The stability indicator
[STAB] turns OFF
SET
LOCK
● Dark ON
The control output turns off at Light ON status and turns on
at Light OFF status.
<How to set sensitivity>
The setting order are same as Light ON mode except ③ &
⑤. The ③ & ⑤ order is opposite from Light ON.
- ③ state
Diffuse reflective: Press the [ON] button without a sensing target.
Through-beam: Press the [ON] button with a sensing target.
<Diffuse reflective >
Mark (Low
reflectance)
Background
(High
reflectance)
Light OFF
- ⑤ state
Diffuse reflective: Press the [OFF] button with a sensing target.
Through-beam: Press the [OFF] button without a sensing target.
<Diffuse reflective >
Mark (Low
reflectance)
Background
(High
reflectance)
Light ON
Frequency 2
<Through- beam>
Light OFF
<Through- beam>
Light ON
B-37
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/ Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software