Autopilot APCG4LP 매뉴얼 - 페이지 5
{카테고리_이름} Autopilot APCG4LP에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Autopilot APCG4LP 13 페이지. 4 burner co2 generator (lp or ng)
Page 4
APCG4
Pressurize the gas line after connections are verified. Use
soapy water and a spray bottle to check for leaks by spraying
it onto the gas connection (fittings) and watch for bubbles. If
bubbles appear re-secure connection and repeat process.
Using the included power supply, connect the unit to a
controller or timer that will determine the amount of time and
how frequent the generator will operate. The APCG4 requires
24 volts DC. The unit should be operated only with
appropriate controls and/or timers.
The ignition module and firing sequence is activated by the
main power switch located on the side of the APCG4. The
generator has power and is in operation if the green "Power
On" indicator light is on.
Note: DO NOT turn on the generator. After the unit
has been successfully installed, read the Start up
Procedure to ensure safe and proper use of the
GEN-4.
!! WARNING!! A spark is produced from a pair of
electrodes near the tip of the brass burners to ignite the
gas. Keep foreign objects away from electrodes.