AgSense AQUA-TRAC Lite 배선 지침 - 페이지 12
{카테고리_이름} AgSense AQUA-TRAC Lite에 대한 배선 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. AgSense AQUA-TRAC Lite 20 페이지. 2015-18 soil moisture monitoring
Wiring the Campbell Scientific
CS650 / CS655 Sensors to the Aqua Trac Unit
Wiring the CS650 / CS655 sensors:
Find the group of terminals (3) with the group label SDI.
1. Connect the Green wire from the CS Sensor to the terminal marked SDI as shown above.
2. Connect the Clear, Black, and Orange wires from the CS Sensor to the terminal marked
GND as shown above. (above shown using a wire nut to connect all 3 wires together)
3. Connect the Red wire from the CS Sensor to the terminal marked PWR as shown above.
Page 9