Object Description
1
DC connectors ( + ) for connecting the PV strings
2
DC connectors ( − ) for connecting the PV strings
3
Socket for the AC connection plug
4
Slot for the communication connection area (Quick Module/RS485 Quick
Module).
Note: The upper slot is optional and blocked as factory default.
6
Circuit breaker (DC Switch) on the DC side for each inverter
5.2 Connection to the Public Grid (AC)
5.2.1 Conditions for the AC Connection
CAUTION!
Load Disconnection Unit
An individual circuit breaker should be equipped for each inverter in order that the
inverter can be safely disconnected under load.
5.2.2 Connecting to the Public Grid (AC)
Overview of the AC Coupling Socket
A
B
Object
Description
A
Sealing nut
B
Seals
C
Clamp ring
C
D
Object
D
E
F
7 / 15
E
F
Description
Gasket
Female pin and screws
AC Connector body