AvaValley 342WRC20SZ 사용자 설명서 - 페이지 13
{카테고리_이름} AvaValley 342WRC20SZ에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AvaValley 342WRC20SZ 14 페이지. Wine/beverage refrigerators
Troubleshooting
Problem
Possible Cause
Fuse blown or circuit breaker tripped.
Power cord unplugged.
Compressor not running.
Thermostat set too high.
Cabinet in defrost cycle.
Excessive amount of warm product placed in
cabinet.
Prolonged door opening or door ajar.
Condensing units run for
Door gasket(s) not sealing properly.
long periods of time.
Dirty condenser coil.
Evaporator coil iced over.
Thermostat set too warm.
Excessive amount of warm product placed in
cabinet.
Fuse blown or circuit breaker tripped.
Cabinet temperature is
Dirty condenser coil.
too warm.
Evaporator coil iced over.
Low refrigerant levels.
Door is slightly ajar.
Gasket is not sealing properly.
Condensation is
collecting on the cabinet
Relative humidity is above 60%.
and/or floor.
Poor switch connection.
Interior light is not
Bulb is not connected.
working.
Bulb has burned out.
User Manual
Wine Refrigerators
Possible Solution
Replace fuse or reset circuit breaker.
Plug in power cord.
Set thermostat to lower temperature.
Wait for defrost cycle to finish.
Allow adequate time for product to cool down.
Ensure doors are closed when not in use. Avoid opening
doors for long periods of time.
Ensure gaskets are snapped in completely. Remove
gasket and wash with soap and water. Check condition of
gasket and replace if necessary.
Clean the condenser coil.
Unplug unit and allow coil to defrost. Make sure
thermostat is not set too cold. Ensure that door gasket(s)
are sealing properly.
Set thermostat to a lower temperature.
Allow adequate time for product to cool down.
Replace fuse or reset circuit breaker.
Clean the condenser coil.
Ensure doors are closed when not in use. Avoid opening
doors for long periods of time.
Contact a service technician to check refrigerant levels.
Make sure door is completely closed.
Clean, repair, or replace the gasket as necessary.
Move unit to area below relative humidity or lower
humidity level.
Turn of flight switch and turn it back on.
Make sure the bulb is correctly inserted in the socket.
Replace the bulb.
AvaValleyRefrigeration.com