0° C, remove the remaining water from
the inlet hose and the drain pump.
1. Disconnect the mains plug from the
mains socket.
2. Close the water tap.
3. Put the two ends of the inlet hose in
a container and let the water flow out
of the hose.
4. Empty the drain pump. Refer to the
emergency drain procedure.
5. When the drain pump is empty,
install the inlet hose again.
13. TROUBLESHOOTING
13.1 Introduction
The start of the appliance does not occur
or it stops during operation.
First try to find a solution to the problem
(refer to the table). If not, contact the
Authorised Service Centre.
With some problems, the acoustic
signals operate and the display shows
an alarm code:
•
water properly.
13.2 Possible failures
Problem
The programme does
not start.
The appliance does not
fill with water properly.
WARNING!
Refer to Safety chapters.
- The appliance does not fill with
Possible solution
Make sure that the mains plug is connected to the mains sock-
et.
Make sure that the appliance lid is closed.
Make sure that there is not a damaged fuse in the fuse box.
Make sure that the Start/Pause has been pressed.
If the delay start is set, cancel the setting or wait for the end of
countdown.
Deactivate the Child Lock function if it is on.
Make sure that the water tap is open.
WARNING!
Make sure that the
temperature is more than 0
°C before you use the
appliance again. The
manufacturer is not
responsible for damages
caused by low temperatures.
•
- The appliance does not drain
the water.
•
- The appliance door is open or
not closed correctly. Please check the
door!
•
- The mains supply is unstable.
Wait until the mains supply is stable.
•
- The anti-flood device is on.
Disconnect the appliance and close
the water tap. Contact the Authorised
Service Centre.
WARNING!
Deactivate the appliance
before you do the checks.
ENGLISH