Salt ......
Salt
The hardness of the water varies from place to place. If
hard water is used in the dishwasher, deposits will form on
the dishes and utensils.
The appliance is equipped with a special softener that uses
a salt specifically designed to eliminate lime and minerals
from the water.
Loading the Salt into the Softener
Always use salt intended
for use with dishwashers.
The salt container is
located beneath the
lower rack and should be
filled as follows:
1. Remove the lower rack
and then unscrew and
remove the cap from the
salt container;
2. If you are filling the
container for the first
time, fill it with water;
3. Place the end of the funnel (supplied) into the hole and
introduce about 2 kg of salt. It is normal for a small amount
of water to come out of the salt container.
4. Carefully screw the cap back on.
The salt container should be filled up when the low
salt indicator light "S" flashes.
Once you have loaded the salt for the first time, it is normal
that the low salt indicator light stays on or flashes for about
5 consecutive cycles.
Warning: To prevent rust from forming, we advise you to
load the salt before starting a wash cycle.
Adjusting Salt Consumption
The dishwasher is designed to allow for adjusting the
amount of salt consumed based
on the harness of the water
used. This is intended to
optimize and customize the
level of salt consumption so that
it remains at a minimum.
Your Local Water Board can
supply the degree of hardness
of the water
in your area.
To adjust salt consumption, pro-
ceed as follows:
1) Unscrew the cap from the salt container.
2) There is a ring on the container with an arrow on it (see
figure to the side), if necessary, rotate the ring in the anti-
clockwise direction from the "_" setting towards the "+"
sign, based on the hardness of the water being used.
It is recommended that adjustments be made in accord-
ance with the following schema:
Water Hardness
Clarke
°fH
mmol/l
degrees
0 - 14
0 - 17
0 -1,7
14 - 36
18 - 44
1,8 - 4,4
36 - 71
45 - 89 4,5 - 8,9
>71
>89
> 8,9
3
Salt
Autono-
consu-
Selector
my
mption
position
(cycles\2-
(grams/-
kg)
cycle)
/
0
/
"-"
20
60
MED
40
40
"+"
60
25