Problem
The compressor does not
start immediately after
pressing the FROSTMATIC
or after changing the tem-
perature.
Water flows inside the re-
frigerator.
Water flows on the floor.
Temperature cannot be set. The FROSTMATIC or
The temperature in the ap-
pliance is too low/too high.
Side panels of the appli-
ance are warm.
There is too much con-
densed water on the rear
wall of the refrigerator.
Possible cause
The FROSTMATIC function
is switched on.
This is normal, no error has
occurred.
The water outlet is clog-
ged.
Food products prevent wa-
ter from flowing into the
water collector.
The melting water outlet is
not connected to the evap-
orative tray above the com-
pressor.
COOLMATIC function is
switched on.
The temperature regulator
is not set correctly.
The food products temper-
ature is too high.
Many food products were
stored at the same time.
The FROSTMATIC function
is switched on.
This is a normal state
caused by operation of the
heat exchanger.
Door was opened too fre-
quently.
Solution
Refer to "FROSTMATIC func-
tion".
The compressor starts after
some time.
Clean the water outlet.
Make sure that food products
do not touch the rear plate.
Attach the melting water out-
let to the evaporative tray.
Switch off FROSTMATIC or
COOLMATIC manually, or wait
until the function resets auto-
matically to set the tempera-
ture. Refer to "FROSTMATIC
or COOLMATIC function".
Set a higher/lower tempera-
ture.
Let the food products temper-
ature decrease to room tem-
perature before storage.
Store less food products at the
same time.
Refer to "FROSTMATIC func-
tion".
Make sure that there is at least
30 mm of space between each
side of the appliance and the
surrounding furniture when
the ambient temperature ex-
ceeds 38°C.
Open the door only when nec-
essary.