Aqua Flo AQUV AQUV-12R22 소유자 매뉴얼 - 페이지 8
{카테고리_이름} Aqua Flo AQUV AQUV-12R22에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua Flo AQUV AQUV-12R22 16 페이지. Ultraviolet disinfection system
Installing the AQUV Rack System
1. There are two mounting holes on the mounting bracket.
Both of them should be mounted directly on to a
wall stud with appropriate screws to carry the weight of
the unit. Included mounting hardware only works for
studs, they are lag bolts and a hole will need to be drilled
to put them in without cracking the stud.
WARNING!
Do not mount the unit directly on drywall
without appropriate reinforcement
2. Install new plumbing using (Fig 2) as reference of how
the final installation should look.
3. Unscrew the filter sump and remove the sanitary wrap from
the filter cartridges. Reinsert the new cartridge into the
sump and screw the sump back onto the filter. Hand-tighten
only.
CAUTION!
DO NOT USE WRENCH TO TIGHTEN SUMP.
4. Carefully unpack UV lamp and quartz dome. Two o-rings
come with the quartz dome. The thinner o-ring is
installed in the groove of the gland nut.
NOTE
Hold lamp and dome by the ends with
soft, dry gloves or cloth. lamp needs to stay
perfectly clean, any dirt or fingerprints on the
lamp will reduce the life.
5. Gently slide the dome O-ring (thicker) over the top (open end)
of the quartz dome to about 1" from the open end (Fig 4).
6. Gently insert the quartz dome into the gland nut and
gently rotate the dome while pushing in until it goes past
the nut O-ring and touches the inside top end of the
gland nut. (Fig 5).
7. Carefully slide the quartz dome with gland nut attached
into the opening at the top of the UV chamber
(Fig 6A & 6B) and hand-tighten the gland nut into place.
CAUTION!
8
Do not overtighten the gland nut as it can
break the quartz dome.
Broken quartz domes are not covered
under warranty.
8. Slowly open supply-valve and valves before and after UV
system. Check for leaks. Do not proceed to next step
until leaks are fixed.
NOTE
Sediment
Pre-Filter
Drain Port
(Recommended)
Dome O-Ring
Gland Nut
1"
Quartz Dome
TIP: Rotate dome while pushing in
CORRECT
Quartz dome is past gland
nut O-ring and is touching the
inside top end of the gland
nut. Caution: Do not push
hard as it can break the quartz
dome.
Fig.6A
NOTE
Do not use pipe dope or tape on these top
threads before attaching gland nut.
L
L
SIDE VIEW
Quartz Dome
Thinner O-Ring
Quartz
Dome STOP
position
Thicker O-Ring
WRONG
Quartz dome is NOT past
gland nut O-ring and is NOT
TOUCHING the inside top end
of the gland nut.
Fig.5
Fig.4
Fig.6B