Features in sr264-02
Patch file details are listed in Table 2.
Table 2: Patch file details for Patch sr264-02.
Base Software Release File
Patch Release Date
Compressed Patch File Name
Compressed Patch File Size
Patch sr264-02 includes the following resolved issues and enhancements:
PCR: 40360
Module: SWITCH
Factory LED tests (enable/disable switch led test for AT-8800 series
switches only and enable/disable switch stpf) were removed prior to
release 2.6.4. This issue has been resolved.
PCR: 40374
Module: PORTAUTH, USER,
UTILITY
Support has been added for EAP types TLS, TTLS, and PEAP when the
switch is acting as an 802.1x authenticator. See "The Authentication Server"
on page 5 for more information.
PCR: 40414
Module: TM, CORE
Factory Autoburn test caused a switch reboot when BIST started to run.
This issue has been resolved.