Dell Force10 S50N Series 빠른 시작 매뉴얼 - 페이지 12

{카테고리_이름} Dell Force10 S50N Series에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell Force10 S50N Series 25 페이지. Rapid equallogic configuration series configuration introduction array: ps4100 host: vmware esxi
Dell Force10 S50N Series에 대해서도 마찬가지입니다: 구현 매뉴얼 (9 페이지)

Power Supplies

On both the S50N and S50V, either the AC or DC power supplies alone are
sufficient to power the switch. When both AC and DC power supplies are
connected, they act in roughly a 60%/40% load-sharing mode.
WARNING: To prevent electrical shock, make sure the system is grounded
properly. If you do not ground your equipment correctly, excessive emissions
may result. Use a qualified electrician to ensure that the power cables meet
your local electrical requirements.
Fans
Ventilation is side-to-side, with six fans on the left side of the switch as you face
the PSU side.
The fan speed increases when the temperature reaches 72 degrees C, and
decreases to normal speed when the temperature falls to 57 degrees C. The
switch never intentionally stops managing traffic.
Status logging is identified by unit in the system log.
Fan replacement in the field is not offered as an option.

Specifications

Chassis Physical Design

Parameter
Height
Width
Depth
Chassis weight with
factory-installed
components
Rack clearance
required
10
Installing the Hardware
S50N and S50N-DC
Specifications
1.73 inches (4.4 cm)
17.32 inches (44.0 cm) (19"
rack-mountable)
16.73 inches (42.5 cm)
(standard 1 rack unit)
14.41 pounds (approx.) (6.54
kg)
Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)
S50V Specifications
1.73 inches (4.4 cm)
17.32 inches (44.0 cm) (19"
rack-mountable)
16.73 inches (42.5 cm)
(standard 1 rack unit)
14.41 pounds (approx.) (6.54
kg)
Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)