Dell EqualLogic PS Series 하드웨어 사용 설명서 - 페이지 37
{카테고리_이름} Dell EqualLogic PS Series에 대한 하드웨어 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell EqualLogic PS Series 48 페이지. Storage arrays
Dell EqualLogic PS Series에 대해서도 마찬가지입니다: 설정 (2 페이지), 하드웨어 사용 설명서 (50 페이지), 하드웨어 유지 관리 (46 페이지)
4 Maintaining Power Supply and Cooling
Modules
The array can support two hot-swappable power supply and cooling modules.
The array is capable of operating with one power supply cooling module temporarily, but both power
supply cooling modules are required to maintain long-term cooling and reliability of the array.
About Power Supplies
The PS Series array receives power from two power supplies (PSUs).
Depending on the chassis size, your array contains either:
•
Two 700-watt PSUs, used in the 2U array. Each 700W power supply contains two cooling fans.
•
Two 1080-watt PSUs, used in the 4U array. Each 1080W power supply contains four cooling
fans.
The cooling fans contained in the power supply unit are not serviceable. If fan failures occur, the
entire power supply unit must be replaced.
Identifying Power Supply Failures
You can identify a power supply and cooling module failure by any or all of the following methods:
•
LEDs on the power supply and cooling modules. See
•
Messages on the console, in the event log, or in the Group Manager GUI Alarms panel.
•
Group Manager GUI and CLI output. The GUI Member Enclosure window or the CLI
select member name show enclosure
failure.
When viewing the rear of the array, power supply 0 is on the left and power supply 1 is on the right.
Power Supply LEDs
The power supplies and cooling modules have LEDs that indicate their status.
and
Figure 28
Figure 29
command shows a power supply and cooling module
illustrate the power supply LEDs.
Power Supply LEDs on page 31
describes these LEDs.
Table 8
for details.
member
31