Dell PowerVault 221S 매뉴얼 - 페이지 8
{카테고리_이름} Dell PowerVault 221S에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell PowerVault 221S 44 페이지. Dell powervault 220s and 221s systems scsi drive enclosure
Dell PowerVault 221S에 대해서도 마찬가지입니다: 공지 사항 (28 페이지), 펌웨어 업데이트 (14 페이지), 서비스 매뉴얼 (33 페이지)
A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS
•
•
Possible:
•
Not recommended:
•
Web Servers
Web severs are usually high traffic systems where read operations are the most common
disk activity as web pages are requested by users. They can be moderate intranet sites
with minimal traffic internal company traffic or global internet portal sites that receive
hundreds of thousands of users daily. Performance is generally the main concern with
redundancy and data protection being less a concern. For large web sites, usually there
are several web servers responding to client requests and as a result the need for
redundancy and data protection is not as important. Also web servers may not require as
much scalability or disk capacity since website content is relatively static and changes are
usually minor content modifications.
I/O Profile
I/O Profile
(Read/Write)
(Sequential/Random)
95/5
Random
Application
Database
Recommended:
•
PAGE 8
RAID 5 – Recommended for databases that require maximum storage capacity
and only base data protection and performance.
RAID 50 – Recommended for those solutions that require a balance between
storage capacity and performance.
RAID 1 – Possible solution for small databases which do not require high storage
capacity.
RAID0, Concatenated - Not recommended due to lack of redundancy and data
protection
Note: While these configurations are not recommended, they can be configured
and utilized.
• Table 2-7: Web General IO profile
Bandwidth
Moderate
• Table 2-8: Web RAID Guidelines
Concatenated
Recommended
RAID 10 – Recommended for enterprise web server solutions where availability
and redundancy and performance are the highest priority, usually stand-alone
portal sites that is critical to the organization's business.
Latency
IO Size
Sensitivity
< 64K
Moderate
RAID Level
0
1
10
Not Recommended
VER A02
Growth
Criticality
Rate
Low
High
5
50
Possible
11/17/2005