Dell VxRail E660 설치 및 서비스 매뉴얼 - 페이지 32

{카테고리_이름} Dell VxRail E660에 대한 설치 및 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell VxRail E660 32 페이지.
Dell VxRail E660에 대해서도 마찬가지입니다: 설치 및 서비스 매뉴얼 (32 페이지)

Dell VxRail E660 설치 및 서비스 매뉴얼
Run the Embedded System Diagnostics from the Dell Lifecycle Controller
Steps
1. When the system is booting, press F10.
2. Select Hardware Diagnostics → Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics
start executing the tests on all the detected devices.
Run the Embedded System Diagnostics from Boot Manager
If your system does not boot, run the Embedded System Diagnostics (ePSA).
Steps
1. When the system is booting, press F11.
2. Use the up arrow and down arrow keys to select System Utilities > Launch Diagnostics.
3. Alternatively, when the system is booting, press F10, select Hardware Diagnostics > Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics
starts executing the tests on all the detected devices.
System diagnostic controls
The following table describes the options available on the System diagnostic controls screen:
Menu
Configuration
Results
System health
Event log
32
System diagnostics and indicator codes
Description
Displays the configuration and status information of all detected devices.
Displays the results of all tests that are run.
Provides the current overview of the system performance.
Displays a time-stamped log of the results of all tests run on the system. This is
displayed if at least one event description is recorded.