{카테고리_이름} Dell Force 10에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell Force 10 29 페이지. Implementing fcoe in the linux operating system
Implementing FCoE in the Linux Operating System
Figure 16.
3. Click OK and then Quit to return to the command prompt. The FCoE client should now start as
part of SLES 11 SP2s boot process, and the FCoE LUNs should be available after the system
boots.
Troubleshooting
Various conditions may exist on the network that interferes with FIPS snooping, particularly on
congested networks.
If the FCoE client is unable to see the FCoE VLAN after booting, restart the lldpad and fcoe
daemons as a troubleshooting step.
1. To restart the lldpad and fcoe daemons, run the following commands:
rcfcoe stop; rclldpad stop; rclldpad start; rcfcoe start
2. Then check the FCoE VLAN status by running fcoeadm -i . Figure 17 shows VLAN status
details.
Configure FCoE to start at system boot.