Dell Force10 Software Defined Networking 배포 매뉴얼 - 페이지 10

{카테고리_이름} Dell Force10 Software Defined Networking에 대한 배포 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dell Force10 Software Defined Networking 36 페이지. Z series software-defined networking (sdn) deployment guide version 1.0

Parameter Type
Parameters
Optional match fields
Mandatory actions
Optional actions
OFPAT_SET_VLAN is optional for OpenFlow (OF) ports and mandatory for OF virtual local area
networks (VLANs).

L2 Flows

Parameter Type
Parameters
Mandatory match
fields
Optional match fields All fields other than dl_vlan and dl_dst must be wildcards.
Mandatory actions
Single OFPAT_OUTPUT action to a switch port.
Optional actions
None.

Learning Bridge (LB) Flows

Parameter Type
Parameters
Mandatory match
fields
Optional match fields All fields other than the ones listed in "Mandatory match fields" must be wildcards.
Mandatory actions
Single OFPAT_OUTPUT action to a switch port.
Optional actions
None.

Max Limits

This section defines the maximum number of permitted flow types. The number of available flow types varies depending
on the type of flow.
You can provision up to eight OF instances on each switch.
The number of flows supported on each switch depends on the flow type.
10
nw_dst (dst-ip)
All fields other than the ones listed in "Mandatory match fields" and "Optional match
fields" must be wildcards.
You must specify set_dl_src (set src-mac) as the port mac (local mac) for the
swtich.
set_dl_dst (set dst-mac)
Single OFPAT_OUTPUT action to a switch port.
dl_vlan (input vlan id)
dl_dst (dst-mac)
dl_src (src-mac)
dl_dst (dst-mac)
LB flows will only be installed in the L2 table if bidirectional traffic is present.