Installation
Recirculation
If site conditions are not suitable for the
rangehood to be used with air
extraction, the appliance must be set
up for recirculation.
For this, conversion kit DUU 151
(available from your Miele Chartered
Agent or Miele ) is required. One
conversion kit is required for the
DA 2250 and 2270, and two kits for the
DA 2210.
You will also require two charcoal filters
for the DA 2250 and 2270, or 4
charcoal filters for the DA 2210 (see
"Technical data").
30
A non-return flap is not used in
recirculation mode.
^ Take the on-site conditions into
account when fitting the conversion
kit.
When fitting the exhaust grille, make
sure that the slats in the grille point
towards the centre of the room and
not directly towards a wall or the
ceiling.
^ Fit the charcoal filters and set the
filter operating hours counter (see
"Cleaning and Care").